{"title":"分布初期故障和异常事件:来自现场记录数据的案例研究","authors":"C. Benner, B. Russell","doi":"10.1109/CPRE.2004.238414","DOIUrl":null,"url":null,"abstract":"A typical distribution circuit consists of thousands of individual components, from transformers to switches to insulators. Failure of a single component can cause service quality and reliability problems for the entire circuit and even adjacent circuits. Under the sponsorship of the Electric Power Research Institute (EPRI), and with the cooperation of EPRI utility members, researchers at Texas A&M University have put in place an advanced, multi-site monitoring system. This system instruments dozens of circuits at multiple utility company substations across the United States and Canada. Extensive data from this multi-site monitoring system have documented numerous examples of incipient fault behavior preceding component failures.","PeriodicalId":305674,"journal":{"name":"57th Annual Conference for Protective Relay Engineers, 2004","volume":"85 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Distribution incipient faults and abnormal events: case studies from recorded field data\",\"authors\":\"C. Benner, B. Russell\",\"doi\":\"10.1109/CPRE.2004.238414\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A typical distribution circuit consists of thousands of individual components, from transformers to switches to insulators. Failure of a single component can cause service quality and reliability problems for the entire circuit and even adjacent circuits. Under the sponsorship of the Electric Power Research Institute (EPRI), and with the cooperation of EPRI utility members, researchers at Texas A&M University have put in place an advanced, multi-site monitoring system. This system instruments dozens of circuits at multiple utility company substations across the United States and Canada. Extensive data from this multi-site monitoring system have documented numerous examples of incipient fault behavior preceding component failures.\",\"PeriodicalId\":305674,\"journal\":{\"name\":\"57th Annual Conference for Protective Relay Engineers, 2004\",\"volume\":\"85 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"57th Annual Conference for Protective Relay Engineers, 2004\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPRE.2004.238414\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"57th Annual Conference for Protective Relay Engineers, 2004","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2004.238414","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

典型的配电线路由数千个独立的部件组成,从变压器到开关再到绝缘体。单个元件的故障会导致整个电路甚至相邻电路的服务质量和可靠性问题。在电力研究所(EPRI)的赞助下,在EPRI公用事业成员的合作下,德克萨斯农工大学的研究人员已经建立了一个先进的多站点监测系统。该系统在美国和加拿大的多个公用事业公司变电站测量了数十个电路。从这个多站点监测系统中获得的大量数据记录了许多在组件故障之前的早期故障行为的例子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Distribution incipient faults and abnormal events: case studies from recorded field data
A typical distribution circuit consists of thousands of individual components, from transformers to switches to insulators. Failure of a single component can cause service quality and reliability problems for the entire circuit and even adjacent circuits. Under the sponsorship of the Electric Power Research Institute (EPRI), and with the cooperation of EPRI utility members, researchers at Texas A&M University have put in place an advanced, multi-site monitoring system. This system instruments dozens of circuits at multiple utility company substations across the United States and Canada. Extensive data from this multi-site monitoring system have documented numerous examples of incipient fault behavior preceding component failures.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信