在跑步机上测量不同最大跑步速度受试者的力-速度关系和功率输出

A. Jaskólska, P. Goossens, B. Veenstra, A. Jaskólskp, J. Skinner
{"title":"在跑步机上测量不同最大跑步速度受试者的力-速度关系和功率输出","authors":"A. Jaskólska, P. Goossens, B. Veenstra, A. Jaskólskp, J. Skinner","doi":"10.1080/15438629909512537","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to estimate the gross body force‐velocity (F‐V) relationship on a newly developed motorized treadmill (Gymrol, France) in subjects who differed in their predicted maximal running velocity (Vmax) calculated from the F‐V relationship. Of the 32 subjects tested, those with the 14 highest Vmax values were assigned to a fast group (FG) and those with the lowest 13 Vmax values to a slow group (SG). The F‐ V relationship during two testing sessions was obtained from six 5‐s, all‐out sprints against different resistance settings that were 5%, 8%, 10%, 13%, 15% and 20% of the maximal value the treadmill could produce. The F‐V relationship fitted a linear regression in both groups. The individual correlation coefficients for the F‐ V relationship during the first session ranged from —0.992 to —0.997, and during the second session from —0.989 to —0.998, with no significant differences between sessions. The Vmax was significantly higher in FG (Vmax = 7.20±0.32m/s) than in the SG (Vmax = ...","PeriodicalId":403174,"journal":{"name":"Sports Medicine, Training and Rehabilitation","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Treadmill measurement of the force‐velocity relationship and power output in subjects with different maximal running velocities\",\"authors\":\"A. Jaskólska, P. Goossens, B. Veenstra, A. Jaskólskp, J. Skinner\",\"doi\":\"10.1080/15438629909512537\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this study was to estimate the gross body force‐velocity (F‐V) relationship on a newly developed motorized treadmill (Gymrol, France) in subjects who differed in their predicted maximal running velocity (Vmax) calculated from the F‐V relationship. Of the 32 subjects tested, those with the 14 highest Vmax values were assigned to a fast group (FG) and those with the lowest 13 Vmax values to a slow group (SG). The F‐ V relationship during two testing sessions was obtained from six 5‐s, all‐out sprints against different resistance settings that were 5%, 8%, 10%, 13%, 15% and 20% of the maximal value the treadmill could produce. The F‐V relationship fitted a linear regression in both groups. The individual correlation coefficients for the F‐ V relationship during the first session ranged from —0.992 to —0.997, and during the second session from —0.989 to —0.998, with no significant differences between sessions. The Vmax was significantly higher in FG (Vmax = 7.20±0.32m/s) than in the SG (Vmax = ...\",\"PeriodicalId\":403174,\"journal\":{\"name\":\"Sports Medicine, Training and Rehabilitation\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sports Medicine, Training and Rehabilitation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/15438629909512537\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sports Medicine, Training and Rehabilitation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/15438629909512537","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

摘要

本研究的目的是在一种新开发的电动跑步机上(法国Gymrol),在根据F - V关系计算的最大跑步速度(Vmax)不同的受试者中,估计总身体力-速度(F - V)的关系。在接受测试的32名受试者中,Vmax值最高的14名被分配到快速组(FG), Vmax值最低的13名被分配到慢速组(SG)。两次测试期间的F - V关系是通过6次5 - s全速冲刺,在不同的阻力设置下获得的,分别是跑步机所能产生的最大值的5%、8%、10%、13%、15%和20%。两组的F - V关系均符合线性回归。在第一次会话中,F - V关系的个体相关系数范围为-0.992至-0.997,在第二次会话中为-0.989至-0.998,会话之间无显著差异。FG组Vmax = 7.20±0.32m/s显著高于SG组(Vmax =…
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Treadmill measurement of the force‐velocity relationship and power output in subjects with different maximal running velocities
The purpose of this study was to estimate the gross body force‐velocity (F‐V) relationship on a newly developed motorized treadmill (Gymrol, France) in subjects who differed in their predicted maximal running velocity (Vmax) calculated from the F‐V relationship. Of the 32 subjects tested, those with the 14 highest Vmax values were assigned to a fast group (FG) and those with the lowest 13 Vmax values to a slow group (SG). The F‐ V relationship during two testing sessions was obtained from six 5‐s, all‐out sprints against different resistance settings that were 5%, 8%, 10%, 13%, 15% and 20% of the maximal value the treadmill could produce. The F‐V relationship fitted a linear regression in both groups. The individual correlation coefficients for the F‐ V relationship during the first session ranged from —0.992 to —0.997, and during the second session from —0.989 to —0.998, with no significant differences between sessions. The Vmax was significantly higher in FG (Vmax = 7.20±0.32m/s) than in the SG (Vmax = ...
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信