低功率Nd: YAG激光星状神经节照射的效果

道生 金子, 秀 松下, 麦夫 加藤, 憲司 吉田, 昌彦 深谷
{"title":"低功率Nd: YAG激光星状神经节照射的效果","authors":"道生 金子, 秀 松下, 麦夫 加藤, 憲司 吉田, 昌彦 深谷","doi":"10.5984/JJPNSOCLASERDENT.4.33","DOIUrl":null,"url":null,"abstract":"The authors have tried previously to substitute a conventional stellate ganglionblock use of local regional anesthetic agents with low power output laser irradiation on thestellate ganglion. It is necessary for the clarification of a function mechanism compare bothmethods.However, stellate ganglion blocking could not be carried out because it was difficult to getsubjects. Fortunately we were recently able to get some volunteers to help us. In this papera comparison between the conventional stellate ganglion block that uses local anestheticagents and low power output Nd: YAG laser irradiation on the stellate ganglion is described.Facial cutaneous temperature, blood pressure and the pulse rate were measured. Facialcutaneous temperatures were analyzed from the image. (J. Jpn. Soc. Laser Dent. 4: 33-38, 1993 Reprint requests to Dr. Kaneko)","PeriodicalId":187459,"journal":{"name":"Journal of Japanese Society for Laser Dentistry","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"低出力 Nd: YAG レーザー星状神経節照射の効果について\",\"authors\":\"道生 金子, 秀 松下, 麦夫 加藤, 憲司 吉田, 昌彦 深谷\",\"doi\":\"10.5984/JJPNSOCLASERDENT.4.33\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors have tried previously to substitute a conventional stellate ganglionblock use of local regional anesthetic agents with low power output laser irradiation on thestellate ganglion. It is necessary for the clarification of a function mechanism compare bothmethods.However, stellate ganglion blocking could not be carried out because it was difficult to getsubjects. Fortunately we were recently able to get some volunteers to help us. In this papera comparison between the conventional stellate ganglion block that uses local anestheticagents and low power output Nd: YAG laser irradiation on the stellate ganglion is described.Facial cutaneous temperature, blood pressure and the pulse rate were measured. Facialcutaneous temperatures were analyzed from the image. (J. Jpn. Soc. Laser Dent. 4: 33-38, 1993 Reprint requests to Dr. Kaneko)\",\"PeriodicalId\":187459,\"journal\":{\"name\":\"Journal of Japanese Society for Laser Dentistry\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Japanese Society for Laser Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5984/JJPNSOCLASERDENT.4.33\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Japanese Society for Laser Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5984/JJPNSOCLASERDENT.4.33","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

作者以前曾尝试用低功率输出激光照射星状神经节来替代传统的星状神经节阻滞。比较两种方法的作用机理是有必要的。然而,星状神经节阻滞由于难以获得受试者而无法进行。幸运的是,我们最近找到了一些志愿者来帮助我们。本文比较了传统的局部麻醉星状神经节阻滞与低功率输出Nd: YAG激光照射星状神经节的效果。测量面部皮肤温度、血压和脉搏率。从图像中分析面部皮肤温度。(j .日本。Soc。《激光凹痕》,1993年第4期:33-38,转载请求Kaneko博士)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
低出力 Nd: YAG レーザー星状神経節照射の効果について
The authors have tried previously to substitute a conventional stellate ganglionblock use of local regional anesthetic agents with low power output laser irradiation on thestellate ganglion. It is necessary for the clarification of a function mechanism compare bothmethods.However, stellate ganglion blocking could not be carried out because it was difficult to getsubjects. Fortunately we were recently able to get some volunteers to help us. In this papera comparison between the conventional stellate ganglion block that uses local anestheticagents and low power output Nd: YAG laser irradiation on the stellate ganglion is described.Facial cutaneous temperature, blood pressure and the pulse rate were measured. Facialcutaneous temperatures were analyzed from the image. (J. Jpn. Soc. Laser Dent. 4: 33-38, 1993 Reprint requests to Dr. Kaneko)
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信