焊盘几何形状对陶瓷球栅阵列焊点可靠性的影响

S. Yee, H. Ladhar
{"title":"焊盘几何形状对陶瓷球栅阵列焊点可靠性的影响","authors":"S. Yee, H. Ladhar","doi":"10.1109/IEMT.1996.559742","DOIUrl":null,"url":null,"abstract":"The reliability of the solder joints on dog bone pads with hot air solder levelling (HASL) finish was found to be statistically different and less reliable than other combinations. The reliability of all other combinations was not significantly different. Both pad geometries and surface finishes evaluated in this study produced excellent, reliable solder joints. The selection of the pad geometry and surface finish will not have significant impact on CBGA solder joint reliability. Since the study was based on mechanical deflection system (MDS) test technology, the limitations for MDS will apply. Additional accelerated thermal cycling (ATC) tests to verify the conclusion will definitely be of value.","PeriodicalId":177653,"journal":{"name":"Nineteenth IEEE/CPMT International Electronics Manufacturing Technology Symposium","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"The influence of pad geometry on ceramic ball grid array solder joint reliability\",\"authors\":\"S. Yee, H. Ladhar\",\"doi\":\"10.1109/IEMT.1996.559742\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The reliability of the solder joints on dog bone pads with hot air solder levelling (HASL) finish was found to be statistically different and less reliable than other combinations. The reliability of all other combinations was not significantly different. Both pad geometries and surface finishes evaluated in this study produced excellent, reliable solder joints. The selection of the pad geometry and surface finish will not have significant impact on CBGA solder joint reliability. Since the study was based on mechanical deflection system (MDS) test technology, the limitations for MDS will apply. Additional accelerated thermal cycling (ATC) tests to verify the conclusion will definitely be of value.\",\"PeriodicalId\":177653,\"journal\":{\"name\":\"Nineteenth IEEE/CPMT International Electronics Manufacturing Technology Symposium\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nineteenth IEEE/CPMT International Electronics Manufacturing Technology Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMT.1996.559742\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nineteenth IEEE/CPMT International Electronics Manufacturing Technology Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMT.1996.559742","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

与其他组合相比,采用热风调平(HASL)抛光的狗骨垫焊点的可靠性存在统计学差异,可靠性较低。其他组合的信度无显著差异。在本研究中评估的焊盘几何形状和表面光洁度都产生了优秀、可靠的焊点。焊盘几何形状和表面光洁度的选择不会对CBGA焊点的可靠性产生重大影响。由于该研究是基于机械挠度系统(MDS)测试技术,因此MDS的局限性将会存在。额外的加速热循环(ATC)测试来验证结论肯定是有价值的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The influence of pad geometry on ceramic ball grid array solder joint reliability
The reliability of the solder joints on dog bone pads with hot air solder levelling (HASL) finish was found to be statistically different and less reliable than other combinations. The reliability of all other combinations was not significantly different. Both pad geometries and surface finishes evaluated in this study produced excellent, reliable solder joints. The selection of the pad geometry and surface finish will not have significant impact on CBGA solder joint reliability. Since the study was based on mechanical deflection system (MDS) test technology, the limitations for MDS will apply. Additional accelerated thermal cycling (ATC) tests to verify the conclusion will definitely be of value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信