{"title":"基于视在功率平均值变化率的功率摆动检测","authors":"Behrooz Taheri, F. Razavi, Sirus Salehimehr","doi":"10.1109/IPAPS.2019.8642060","DOIUrl":null,"url":null,"abstract":"Power swing is a transient phenomenon in the power system that occurred by several reasons include line outage, a sudden increase or decrease in load, fault and etc. The power swing may cause entering the impedance seen by distance relay into its protective zones and causing to the undesirable operation of this relay. This undesirable operation of distance relay may cause create an instability in the power network and subsequently leading to blackouts. In this paper, a new method for power swing detection using the variation rates of the average value of apparent power is proposed. The proposed method has been tested using Digsilent and Matlab software in the standard two-area network.","PeriodicalId":173653,"journal":{"name":"2019 International Conference on Protection and Automation of Power System (IPAPS)","volume":"227 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Power Swing Detection Using the Variation Rates of the Average Value of Apparent Power\",\"authors\":\"Behrooz Taheri, F. Razavi, Sirus Salehimehr\",\"doi\":\"10.1109/IPAPS.2019.8642060\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power swing is a transient phenomenon in the power system that occurred by several reasons include line outage, a sudden increase or decrease in load, fault and etc. The power swing may cause entering the impedance seen by distance relay into its protective zones and causing to the undesirable operation of this relay. This undesirable operation of distance relay may cause create an instability in the power network and subsequently leading to blackouts. In this paper, a new method for power swing detection using the variation rates of the average value of apparent power is proposed. The proposed method has been tested using Digsilent and Matlab software in the standard two-area network.\",\"PeriodicalId\":173653,\"journal\":{\"name\":\"2019 International Conference on Protection and Automation of Power System (IPAPS)\",\"volume\":\"227 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Protection and Automation of Power System (IPAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPAPS.2019.8642060\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Protection and Automation of Power System (IPAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPAPS.2019.8642060","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Power Swing Detection Using the Variation Rates of the Average Value of Apparent Power
Power swing is a transient phenomenon in the power system that occurred by several reasons include line outage, a sudden increase or decrease in load, fault and etc. The power swing may cause entering the impedance seen by distance relay into its protective zones and causing to the undesirable operation of this relay. This undesirable operation of distance relay may cause create an instability in the power network and subsequently leading to blackouts. In this paper, a new method for power swing detection using the variation rates of the average value of apparent power is proposed. The proposed method has been tested using Digsilent and Matlab software in the standard two-area network.