{"title":"蒸压加气混凝土隔热对单户住宅能源性能的影响","authors":"I. Kirakevych, M. Sanytsky, Danylo Kotur","doi":"10.23939/jtbp2023.01.043","DOIUrl":null,"url":null,"abstract":"The article examines the effect of thermal insulation from autoclaved aerated concrete on the energy characteristics of a single-family house. Analysis of mathematical models of energy characteristics of external enclosing structures of buildings depending on the thickness of AEROC autoclaved concrete products according to the criteria of heat loss shows that the thermal resistance value of 7.11 m2K/W and the heat transfer coefficient of 0.141 W/(m2K) are achieved using the wall block AEROC D 300 and AEROC Energy thermal insulation panel with a thickness of 200 mm. These indicators correspond to the passive house standard for thermal resistance (Ro ≥ 6.7 m2K/W) and heat transfer coefficient (Uo ≤ 0.15 W/m2K) of external walls, which confirms the feasibility of using AEROC Energy D 150 thermal insulation panels in combination with wall blocks AEROC D 300 for housing construction according to passive construction standards.","PeriodicalId":369033,"journal":{"name":"Theory and Building Practice","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of thermal insulation from autoclaved aerated concrete on the energy performance of a single-family house\",\"authors\":\"I. Kirakevych, M. Sanytsky, Danylo Kotur\",\"doi\":\"10.23939/jtbp2023.01.043\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article examines the effect of thermal insulation from autoclaved aerated concrete on the energy characteristics of a single-family house. Analysis of mathematical models of energy characteristics of external enclosing structures of buildings depending on the thickness of AEROC autoclaved concrete products according to the criteria of heat loss shows that the thermal resistance value of 7.11 m2K/W and the heat transfer coefficient of 0.141 W/(m2K) are achieved using the wall block AEROC D 300 and AEROC Energy thermal insulation panel with a thickness of 200 mm. These indicators correspond to the passive house standard for thermal resistance (Ro ≥ 6.7 m2K/W) and heat transfer coefficient (Uo ≤ 0.15 W/m2K) of external walls, which confirms the feasibility of using AEROC Energy D 150 thermal insulation panels in combination with wall blocks AEROC D 300 for housing construction according to passive construction standards.\",\"PeriodicalId\":369033,\"journal\":{\"name\":\"Theory and Building Practice\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Theory and Building Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23939/jtbp2023.01.043\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Theory and Building Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23939/jtbp2023.01.043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本文考察了保温效果从蒸压加气混凝土对单户住宅的能源特性。根据热损失准则对AEROC蒸压混凝土产品厚度对建筑围护结构能量特性影响的数学模型进行分析,结果表明,采用AEROC D 300墙体砌块和厚度为200 mm的AEROC能量保温板,其热阻值为7.11 m2K/W,换热系数为0.141 W/(m2K)。这些指标符合被动式房屋外墙热阻(Ro≥6.7 m2K/W)和传热系数(Uo≤0.15 W/m2K)标准,证实了按照被动式建筑标准,采用AEROC Energy D 150绝热板结合墙块AEROC D 300进行房屋施工的可行性。
The effect of thermal insulation from autoclaved aerated concrete on the energy performance of a single-family house
The article examines the effect of thermal insulation from autoclaved aerated concrete on the energy characteristics of a single-family house. Analysis of mathematical models of energy characteristics of external enclosing structures of buildings depending on the thickness of AEROC autoclaved concrete products according to the criteria of heat loss shows that the thermal resistance value of 7.11 m2K/W and the heat transfer coefficient of 0.141 W/(m2K) are achieved using the wall block AEROC D 300 and AEROC Energy thermal insulation panel with a thickness of 200 mm. These indicators correspond to the passive house standard for thermal resistance (Ro ≥ 6.7 m2K/W) and heat transfer coefficient (Uo ≤ 0.15 W/m2K) of external walls, which confirms the feasibility of using AEROC Energy D 150 thermal insulation panels in combination with wall blocks AEROC D 300 for housing construction according to passive construction standards.