{"title":"金属材料制造厂的噪音监测系统","authors":"김병삼, 박진영, 서양, 김정기, 이원형, 이경훈","doi":"10.17958/KSMT.22.1.202002.1","DOIUrl":null,"url":null,"abstract":"Recently, as the quality of life of modern people improves, interest in environmental noise is gradually increasing. As the public's awareness of environmental rights increased, it was necessary to grasp the actual condition of the noise source and systematic noise management plan. The data is expected to be used as a response to noise-related complaints. As a result measured using the factory noise monitoring system, the amount of data measured every 5 minutes from 00:00 to 24:00 can obtain 288 noise levels and frequency characteristics per day, and frequency using 1/3 octave-band. The analysis reveals what frequency range affects the noise from the metal working plant near the office. In addition, it can be seen that it is possible to compare with the reference value by using the stored data divided into night time, day time, and evening time for each time zone, and it is determined that it is possible to secure smooth data about the noise source to be measured.","PeriodicalId":168106,"journal":{"name":"Journal of the Korean Society of Mechanical Technology","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"금속재료품 제조공장의 소음 모니터링 시스템\",\"authors\":\"김병삼, 박진영, 서양, 김정기, 이원형, 이경훈\",\"doi\":\"10.17958/KSMT.22.1.202002.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, as the quality of life of modern people improves, interest in environmental noise is gradually increasing. As the public's awareness of environmental rights increased, it was necessary to grasp the actual condition of the noise source and systematic noise management plan. The data is expected to be used as a response to noise-related complaints. As a result measured using the factory noise monitoring system, the amount of data measured every 5 minutes from 00:00 to 24:00 can obtain 288 noise levels and frequency characteristics per day, and frequency using 1/3 octave-band. The analysis reveals what frequency range affects the noise from the metal working plant near the office. In addition, it can be seen that it is possible to compare with the reference value by using the stored data divided into night time, day time, and evening time for each time zone, and it is determined that it is possible to secure smooth data about the noise source to be measured.\",\"PeriodicalId\":168106,\"journal\":{\"name\":\"Journal of the Korean Society of Mechanical Technology\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Korean Society of Mechanical Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17958/KSMT.22.1.202002.1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Society of Mechanical Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17958/KSMT.22.1.202002.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Recently, as the quality of life of modern people improves, interest in environmental noise is gradually increasing. As the public's awareness of environmental rights increased, it was necessary to grasp the actual condition of the noise source and systematic noise management plan. The data is expected to be used as a response to noise-related complaints. As a result measured using the factory noise monitoring system, the amount of data measured every 5 minutes from 00:00 to 24:00 can obtain 288 noise levels and frequency characteristics per day, and frequency using 1/3 octave-band. The analysis reveals what frequency range affects the noise from the metal working plant near the office. In addition, it can be seen that it is possible to compare with the reference value by using the stored data divided into night time, day time, and evening time for each time zone, and it is determined that it is possible to secure smooth data about the noise source to be measured.