{"title":"三相z源交流-交流变换器","authors":"Xupeng Fang","doi":"10.1109/EPEPEMC.2006.4778469","DOIUrl":null,"url":null,"abstract":"The paper proposes a novel three-phase Z-source ac-ac converter topology, presents its circuit configuration, operating principle and control method. The proposed ac-ac converter employs a unique LC network to suppress the over-current and surge voltage due to the shoot-through or the open-circuit of the two switches. By controlling the duty cycle, the Z-source can provide buck-boost function, produce greater or less voltage than the line voltage. As a result, the new Z-source ac-ac converter reduces line harmonics, improves power factor and reliability. Analysis, simulation and experimental results are presented to demonstrate these new features.","PeriodicalId":401288,"journal":{"name":"2006 12th International Power Electronics and Motion Control Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":"{\"title\":\"Three-Phase Z-Source AC-AC Converter\",\"authors\":\"Xupeng Fang\",\"doi\":\"10.1109/EPEPEMC.2006.4778469\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper proposes a novel three-phase Z-source ac-ac converter topology, presents its circuit configuration, operating principle and control method. The proposed ac-ac converter employs a unique LC network to suppress the over-current and surge voltage due to the shoot-through or the open-circuit of the two switches. By controlling the duty cycle, the Z-source can provide buck-boost function, produce greater or less voltage than the line voltage. As a result, the new Z-source ac-ac converter reduces line harmonics, improves power factor and reliability. Analysis, simulation and experimental results are presented to demonstrate these new features.\",\"PeriodicalId\":401288,\"journal\":{\"name\":\"2006 12th International Power Electronics and Motion Control Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"23\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 12th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEPEMC.2006.4778469\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 12th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEPEMC.2006.4778469","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The paper proposes a novel three-phase Z-source ac-ac converter topology, presents its circuit configuration, operating principle and control method. The proposed ac-ac converter employs a unique LC network to suppress the over-current and surge voltage due to the shoot-through or the open-circuit of the two switches. By controlling the duty cycle, the Z-source can provide buck-boost function, produce greater or less voltage than the line voltage. As a result, the new Z-source ac-ac converter reduces line harmonics, improves power factor and reliability. Analysis, simulation and experimental results are presented to demonstrate these new features.