微电网中的电源管理:并网孤岛运行模式分析

N. Choudhary, S. Mohanty, Ravindra K. Singh
{"title":"微电网中的电源管理:并网孤岛运行模式分析","authors":"N. Choudhary, S. Mohanty, Ravindra K. Singh","doi":"10.11591/ijape.v6.i3.pp163-173","DOIUrl":null,"url":null,"abstract":"This paper presents an investigation about the impact of integrating renewable energy based generation sources on the existing distribution system in terms of load sharing. The study of load sharing among various distributed generators (DGs) and utility grid has been performed for two cases: (a) when equivalent source based DG is connected and (b) when real PV/Fuel cell based DG is properly integrated to the distribution system. The real photovoltaic and fuel cell based DG do not behave as stiff current/voltage source due to disturbances happening either internally in system known as parametric uncertainties or due to external disturbances like weather conditions, load change etc. Further it has been observed with extensive analysis using simulation result, that even though all DGs are of equal capacity in their generation but when the load is either increased or decreased this doesn’t essentially guarantee that all DGs will equally share the active and reactive power demand Full Text: PDF DOI: http://dx.doi.org/10.11591/ijape.v6.i3.pp163-173","PeriodicalId":280098,"journal":{"name":"International Journal of Applied Power Engineering","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Power Management in Microgrid: Analysis in Grid Connected and Islanded Mode of Operation\",\"authors\":\"N. Choudhary, S. Mohanty, Ravindra K. Singh\",\"doi\":\"10.11591/ijape.v6.i3.pp163-173\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an investigation about the impact of integrating renewable energy based generation sources on the existing distribution system in terms of load sharing. The study of load sharing among various distributed generators (DGs) and utility grid has been performed for two cases: (a) when equivalent source based DG is connected and (b) when real PV/Fuel cell based DG is properly integrated to the distribution system. The real photovoltaic and fuel cell based DG do not behave as stiff current/voltage source due to disturbances happening either internally in system known as parametric uncertainties or due to external disturbances like weather conditions, load change etc. Further it has been observed with extensive analysis using simulation result, that even though all DGs are of equal capacity in their generation but when the load is either increased or decreased this doesn’t essentially guarantee that all DGs will equally share the active and reactive power demand Full Text: PDF DOI: http://dx.doi.org/10.11591/ijape.v6.i3.pp163-173\",\"PeriodicalId\":280098,\"journal\":{\"name\":\"International Journal of Applied Power Engineering\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Power Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11591/ijape.v6.i3.pp163-173\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/ijape.v6.i3.pp163-173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文从负荷分担的角度研究了可再生能源发电对现有配电系统的影响。本文研究了两种情况下各种分布式发电机组(DG)和公用电网之间的负荷分担问题:(a)连接等效源DG和(b)将真正的基于光伏/燃料电池的DG适当地集成到配电系统中。由于系统内部发生的扰动(即参数不确定性)或外部扰动(如天气条件、负载变化等),真实的光伏和基于燃料电池的DG不会表现为刚性电流/电压源。此外,通过使用模拟结果进行广泛分析可以观察到,尽管所有dg在其发电中具有相同的容量,但当负载增加或减少时,这并不能从本质上保证所有dg将平等地共享有功和无功功率需求
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power Management in Microgrid: Analysis in Grid Connected and Islanded Mode of Operation
This paper presents an investigation about the impact of integrating renewable energy based generation sources on the existing distribution system in terms of load sharing. The study of load sharing among various distributed generators (DGs) and utility grid has been performed for two cases: (a) when equivalent source based DG is connected and (b) when real PV/Fuel cell based DG is properly integrated to the distribution system. The real photovoltaic and fuel cell based DG do not behave as stiff current/voltage source due to disturbances happening either internally in system known as parametric uncertainties or due to external disturbances like weather conditions, load change etc. Further it has been observed with extensive analysis using simulation result, that even though all DGs are of equal capacity in their generation but when the load is either increased or decreased this doesn’t essentially guarantee that all DGs will equally share the active and reactive power demand Full Text: PDF DOI: http://dx.doi.org/10.11591/ijape.v6.i3.pp163-173
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信