风力发电机组集成的电网优化

S. Biswas, Raktim Chatterjee, Rahul Pramanik
{"title":"风力发电机组集成的电网优化","authors":"S. Biswas, Raktim Chatterjee, Rahul Pramanik","doi":"10.1109/ICONCE.2014.6808710","DOIUrl":null,"url":null,"abstract":"This paper presents an optimal load flow model in conventional thermal power system to minimize the generation cost, active power losses and reactive power losses by introducing an additional wind generator in the existing system The electrical power demand of the growing concerns totally depends upon the conventional power plants. To satisfy the need of future demand, in view of the non conventional energy perspective as well as to preserve the conventional asset for future we introduce a wind power generator in the system and study the reliability as well as the voltage profile of the proposed system. Employing an approach of simulation at test loading of conventional system, we propose a system to decrease the total loss by using hybrid thermal-wind power system. The Voltage profile of the proposed system has also been tested. It has also been shown that the implementation of the proposed methodology can offer a net saving of generation cost. The proposed algorithm has been tested on standard IEEE 30 bus test system and the results obtained, looked promising.","PeriodicalId":109404,"journal":{"name":"2014 1st International Conference on Non Conventional Energy (ICONCE 2014)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Optimization of electrical power networks with wind generator integration\",\"authors\":\"S. Biswas, Raktim Chatterjee, Rahul Pramanik\",\"doi\":\"10.1109/ICONCE.2014.6808710\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an optimal load flow model in conventional thermal power system to minimize the generation cost, active power losses and reactive power losses by introducing an additional wind generator in the existing system The electrical power demand of the growing concerns totally depends upon the conventional power plants. To satisfy the need of future demand, in view of the non conventional energy perspective as well as to preserve the conventional asset for future we introduce a wind power generator in the system and study the reliability as well as the voltage profile of the proposed system. Employing an approach of simulation at test loading of conventional system, we propose a system to decrease the total loss by using hybrid thermal-wind power system. The Voltage profile of the proposed system has also been tested. It has also been shown that the implementation of the proposed methodology can offer a net saving of generation cost. The proposed algorithm has been tested on standard IEEE 30 bus test system and the results obtained, looked promising.\",\"PeriodicalId\":109404,\"journal\":{\"name\":\"2014 1st International Conference on Non Conventional Energy (ICONCE 2014)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 1st International Conference on Non Conventional Energy (ICONCE 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICONCE.2014.6808710\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 1st International Conference on Non Conventional Energy (ICONCE 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICONCE.2014.6808710","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文提出了传统火电系统的最优负荷潮流模型,通过在现有系统中增加风力发电机,使发电成本、有功功率损耗和无功功率损耗最小化。为了满足未来的需求,从非传统能源的角度出发,同时也为了保护未来的传统资产,我们在系统中引入了风力发电机,并对系统的可靠性和电压分布进行了研究。采用传统系统试验负荷模拟的方法,提出了一种利用热风混合发电系统降低总损耗的系统。所提出的系统的电压分布也进行了测试。还表明,实施拟议的方法可以提供发电成本的净节省。该算法已在标准IEEE 30总线测试系统上进行了测试,取得了良好的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimization of electrical power networks with wind generator integration
This paper presents an optimal load flow model in conventional thermal power system to minimize the generation cost, active power losses and reactive power losses by introducing an additional wind generator in the existing system The electrical power demand of the growing concerns totally depends upon the conventional power plants. To satisfy the need of future demand, in view of the non conventional energy perspective as well as to preserve the conventional asset for future we introduce a wind power generator in the system and study the reliability as well as the voltage profile of the proposed system. Employing an approach of simulation at test loading of conventional system, we propose a system to decrease the total loss by using hybrid thermal-wind power system. The Voltage profile of the proposed system has also been tested. It has also been shown that the implementation of the proposed methodology can offer a net saving of generation cost. The proposed algorithm has been tested on standard IEEE 30 bus test system and the results obtained, looked promising.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信