{"title":"输入开关充电和感应充电双极马克思发电机拓扑性能分析","authors":"N. Pinjari, S. Bindu","doi":"10.1109/ICISIM.2017.8122187","DOIUrl":null,"url":null,"abstract":"This paper deals with design, simulations and comparison of various bipolar Marx topologies. Output voltage pulse specifications are 10 kV, % voltage droop − 10%, PRF − 1kHz and pulse width of 5μsec. The features of inductive charging and charging through input switch is analyzed. Bipolar Marx generator with six switches, five switches and four switch topologies are designed and simulated. These solid-state circuits are charged through a diode and switch. During the erection mode, a pulse current of kiloampere range of short duration is passing through this switch. A comparative analysis is carried out on the output pulse parameters for the Marx modulators.","PeriodicalId":139000,"journal":{"name":"2017 1st International Conference on Intelligent Systems and Information Management (ICISIM)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Performance analysis of bipolar Marx generator topologies with input switch charging and inductive charging method\",\"authors\":\"N. Pinjari, S. Bindu\",\"doi\":\"10.1109/ICISIM.2017.8122187\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with design, simulations and comparison of various bipolar Marx topologies. Output voltage pulse specifications are 10 kV, % voltage droop − 10%, PRF − 1kHz and pulse width of 5μsec. The features of inductive charging and charging through input switch is analyzed. Bipolar Marx generator with six switches, five switches and four switch topologies are designed and simulated. These solid-state circuits are charged through a diode and switch. During the erection mode, a pulse current of kiloampere range of short duration is passing through this switch. A comparative analysis is carried out on the output pulse parameters for the Marx modulators.\",\"PeriodicalId\":139000,\"journal\":{\"name\":\"2017 1st International Conference on Intelligent Systems and Information Management (ICISIM)\",\"volume\":\"82 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 1st International Conference on Intelligent Systems and Information Management (ICISIM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICISIM.2017.8122187\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 1st International Conference on Intelligent Systems and Information Management (ICISIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISIM.2017.8122187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance analysis of bipolar Marx generator topologies with input switch charging and inductive charging method
This paper deals with design, simulations and comparison of various bipolar Marx topologies. Output voltage pulse specifications are 10 kV, % voltage droop − 10%, PRF − 1kHz and pulse width of 5μsec. The features of inductive charging and charging through input switch is analyzed. Bipolar Marx generator with six switches, five switches and four switch topologies are designed and simulated. These solid-state circuits are charged through a diode and switch. During the erection mode, a pulse current of kiloampere range of short duration is passing through this switch. A comparative analysis is carried out on the output pulse parameters for the Marx modulators.