{"title":"用电容性测量方法进行非接触同时两点测量的液体区分","authors":"T. Soejima, K. Shida","doi":"10.1109/SICE.2002.1195472","DOIUrl":null,"url":null,"abstract":"We propose the noncontact liquid distinction by a capacitive measurement sensor with two-layer electrodes structure. Three kinds of liquids, distilled water, sulfuric acid and hydrochloric acid, are distinguished by the change rate of two data obtained with only one time simultaneous measurement of the propose sensor.","PeriodicalId":301855,"journal":{"name":"Proceedings of the 41st SICE Annual Conference. SICE 2002.","volume":"PP 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Liquid distinction by capacitive measurement using non-contact simultaneous two-point measurement method\",\"authors\":\"T. Soejima, K. Shida\",\"doi\":\"10.1109/SICE.2002.1195472\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We propose the noncontact liquid distinction by a capacitive measurement sensor with two-layer electrodes structure. Three kinds of liquids, distilled water, sulfuric acid and hydrochloric acid, are distinguished by the change rate of two data obtained with only one time simultaneous measurement of the propose sensor.\",\"PeriodicalId\":301855,\"journal\":{\"name\":\"Proceedings of the 41st SICE Annual Conference. SICE 2002.\",\"volume\":\"PP 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 41st SICE Annual Conference. SICE 2002.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SICE.2002.1195472\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st SICE Annual Conference. SICE 2002.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2002.1195472","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Liquid distinction by capacitive measurement using non-contact simultaneous two-point measurement method
We propose the noncontact liquid distinction by a capacitive measurement sensor with two-layer electrodes structure. Three kinds of liquids, distilled water, sulfuric acid and hydrochloric acid, are distinguished by the change rate of two data obtained with only one time simultaneous measurement of the propose sensor.