{"title":"具有先进通信和功能的多功能智能电能表的构建原理","authors":"I. A. Magomedov, M. N. Khidivov, A. I. Magomedov","doi":"10.21822/2073-6185-2023-50-1-89-98","DOIUrl":null,"url":null,"abstract":"Objective. Development of principles for the construction of a multifunctional intelligent electric energy meter (MSE) with expanded communication and functional capabilities and the construction of MSE based on them for automated systems of commercial accounting of energy consumption (ASKUE).Method. When developing the principles of the construction of the IEE, an analysis of existing electric energy metering devices was carried out and their main disadvantages were identified, which made it possible to improve the characteristics and expand the functionality of metering devices. The operability of the main components of the IEE is confirmed by the results of mathematical and physical modeling, which showed the possibility of improving the metrological characteristics and technical parameters that determine the quantitative, qualitative and cost characteristics of the devices.Result. The principles of the construction of the IEE have been developed, which makes it possible to create IEE with expanded communication and functional capabilities for the ASUE.Conclusion. Using them in ASCUE posvolit: -to build self-adjusting mesh networks based on them, which can be used in the construction of ASCS with increased survivability; -to ensure the exchange of accounting and service information with the ASKUE over the radio channel, PCL modem and RS-485 (CAN) interface, which increases the reliability of obtaining accounting information and integrate the MISEE into existing ASKUE, because it makes it possible to select the appropriate type of specific ASKUE interface or communication interfaces \"counter-ASKUE\";- regulate energy consumption and independent disconnection of the consumer from the network for each subscriber unit (separately for each subscriber) in case of arrears of payments, network overload and unauthorized access to the nodes and blocks of the meter in various ways;- to improve the operating conditions of the meter when organizing electronic payments and increasing the reliability of accounting information due to contactless remote removal of information by means of communication interfaces for each subscriber or by means of an individual remote control (remote control).-to reduce the hardware costs of servicing one subscriber associated with the use of the main units and units of the meter to account for energy consumption for all subscribers, and, as a result, the low cost of electricity metering in recalculation per subscriber.","PeriodicalId":202454,"journal":{"name":"Herald of Dagestan State Technical University. Technical Sciences","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Principles of construction of a multifunctional intelligent electric energy meter with advanced communication and functional capabilities\",\"authors\":\"I. A. Magomedov, M. N. Khidivov, A. I. Magomedov\",\"doi\":\"10.21822/2073-6185-2023-50-1-89-98\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective. Development of principles for the construction of a multifunctional intelligent electric energy meter (MSE) with expanded communication and functional capabilities and the construction of MSE based on them for automated systems of commercial accounting of energy consumption (ASKUE).Method. When developing the principles of the construction of the IEE, an analysis of existing electric energy metering devices was carried out and their main disadvantages were identified, which made it possible to improve the characteristics and expand the functionality of metering devices. The operability of the main components of the IEE is confirmed by the results of mathematical and physical modeling, which showed the possibility of improving the metrological characteristics and technical parameters that determine the quantitative, qualitative and cost characteristics of the devices.Result. The principles of the construction of the IEE have been developed, which makes it possible to create IEE with expanded communication and functional capabilities for the ASUE.Conclusion. Using them in ASCUE posvolit: -to build self-adjusting mesh networks based on them, which can be used in the construction of ASCS with increased survivability; -to ensure the exchange of accounting and service information with the ASKUE over the radio channel, PCL modem and RS-485 (CAN) interface, which increases the reliability of obtaining accounting information and integrate the MISEE into existing ASKUE, because it makes it possible to select the appropriate type of specific ASKUE interface or communication interfaces \\\"counter-ASKUE\\\";- regulate energy consumption and independent disconnection of the consumer from the network for each subscriber unit (separately for each subscriber) in case of arrears of payments, network overload and unauthorized access to the nodes and blocks of the meter in various ways;- to improve the operating conditions of the meter when organizing electronic payments and increasing the reliability of accounting information due to contactless remote removal of information by means of communication interfaces for each subscriber or by means of an individual remote control (remote control).-to reduce the hardware costs of servicing one subscriber associated with the use of the main units and units of the meter to account for energy consumption for all subscribers, and, as a result, the low cost of electricity metering in recalculation per subscriber.\",\"PeriodicalId\":202454,\"journal\":{\"name\":\"Herald of Dagestan State Technical University. Technical Sciences\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Herald of Dagestan State Technical University. Technical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21822/2073-6185-2023-50-1-89-98\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Herald of Dagestan State Technical University. Technical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21822/2073-6185-2023-50-1-89-98","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目标。开发具有扩展通信和功能的多功能智能电能表(MSE)的构建原理,并在此基础上构建用于商业能耗自动化核算系统(ASKUE)的MSE。在制定IEE的结构原理时,对现有的电能计量装置进行了分析,确定了其主要缺点,从而可以改进计量装置的特性并扩展其功能。数学和物理建模的结果证实了IEE主要部件的可操作性,表明了改进决定设备定量、定性和成本特征的计量特性和技术参数的可能性。建立了独立电子设备的构建原则,为建立具有扩展通信和功能的独立电子设备提供了可能。将它们应用于ASCUE posvolit:在此基础上构建自调整网状网络,可用于构建具有更高生存能力的ASCS;-确保通过无线电信道、PCL调制解调器和RS-485 (CAN)接口与ASKUE交换会计和服务信息,从而增加了获取会计信息的可靠性,并将MISEE集成到现有的ASKUE中;因为它可以选择适当类型的特定ASKUE接口或通信接口“反ASKUE”;-在拖欠付款的情况下,调节能源消耗并独立断开每个用户单位(每个用户单独)的消费者与网络的连接;网络超载和以各种方式未经授权访问电表的节点和块;-通过每个用户的通信接口或通过单个遥控器(遥控器)的非接触式远程删除信息,在组织电子支付时改善电表的操作条件和增加会计信息的可靠性。-减少为一个用户提供服务的硬件成本,这些硬件成本与使用主单位和计量单位计算所有用户的能源消耗有关,从而降低每个用户重新计算电力计量的成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Principles of construction of a multifunctional intelligent electric energy meter with advanced communication and functional capabilities
Objective. Development of principles for the construction of a multifunctional intelligent electric energy meter (MSE) with expanded communication and functional capabilities and the construction of MSE based on them for automated systems of commercial accounting of energy consumption (ASKUE).Method. When developing the principles of the construction of the IEE, an analysis of existing electric energy metering devices was carried out and their main disadvantages were identified, which made it possible to improve the characteristics and expand the functionality of metering devices. The operability of the main components of the IEE is confirmed by the results of mathematical and physical modeling, which showed the possibility of improving the metrological characteristics and technical parameters that determine the quantitative, qualitative and cost characteristics of the devices.Result. The principles of the construction of the IEE have been developed, which makes it possible to create IEE with expanded communication and functional capabilities for the ASUE.Conclusion. Using them in ASCUE posvolit: -to build self-adjusting mesh networks based on them, which can be used in the construction of ASCS with increased survivability; -to ensure the exchange of accounting and service information with the ASKUE over the radio channel, PCL modem and RS-485 (CAN) interface, which increases the reliability of obtaining accounting information and integrate the MISEE into existing ASKUE, because it makes it possible to select the appropriate type of specific ASKUE interface or communication interfaces "counter-ASKUE";- regulate energy consumption and independent disconnection of the consumer from the network for each subscriber unit (separately for each subscriber) in case of arrears of payments, network overload and unauthorized access to the nodes and blocks of the meter in various ways;- to improve the operating conditions of the meter when organizing electronic payments and increasing the reliability of accounting information due to contactless remote removal of information by means of communication interfaces for each subscriber or by means of an individual remote control (remote control).-to reduce the hardware costs of servicing one subscriber associated with the use of the main units and units of the meter to account for energy consumption for all subscribers, and, as a result, the low cost of electricity metering in recalculation per subscriber.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信