Junru Chen, Rongwu Zhu, Marco Liserre, T. O’Donnell
{"title":"配电网不平衡负荷下智能变压器中性点电流减小控制","authors":"Junru Chen, Rongwu Zhu, Marco Liserre, T. O’Donnell","doi":"10.1109/ICIEA.2018.8398108","DOIUrl":null,"url":null,"abstract":"Imbalanced loads arouse neutral current looping in the distribution system, which increases power loss and results in neutral potential variation. Compared to the conventional power transformer, the smart transformer (ST) has advantages on the downstream voltage regulation. Thus, this paper proposes a voltage control strategy based on ST to reduce the LV grid neutral current according with EN 50160 imbalanced voltage standard. The proposed control has been validated in the Matlab/Simulink, and the system performance under the proposed control has been simulated under the imbalanced loading profile in a 400 kVA, 10 kV/400 V distribution network. The results prove the proposed control can practically reduce the neutral current.","PeriodicalId":140420,"journal":{"name":"2018 13th IEEE Conference on Industrial Electronics and Applications (ICIEA)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Neutral current reduction control for smart transformer under the imbalanced load in distribution system\",\"authors\":\"Junru Chen, Rongwu Zhu, Marco Liserre, T. O’Donnell\",\"doi\":\"10.1109/ICIEA.2018.8398108\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Imbalanced loads arouse neutral current looping in the distribution system, which increases power loss and results in neutral potential variation. Compared to the conventional power transformer, the smart transformer (ST) has advantages on the downstream voltage regulation. Thus, this paper proposes a voltage control strategy based on ST to reduce the LV grid neutral current according with EN 50160 imbalanced voltage standard. The proposed control has been validated in the Matlab/Simulink, and the system performance under the proposed control has been simulated under the imbalanced loading profile in a 400 kVA, 10 kV/400 V distribution network. The results prove the proposed control can practically reduce the neutral current.\",\"PeriodicalId\":140420,\"journal\":{\"name\":\"2018 13th IEEE Conference on Industrial Electronics and Applications (ICIEA)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 13th IEEE Conference on Industrial Electronics and Applications (ICIEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEA.2018.8398108\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 13th IEEE Conference on Industrial Electronics and Applications (ICIEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEA.2018.8398108","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Neutral current reduction control for smart transformer under the imbalanced load in distribution system
Imbalanced loads arouse neutral current looping in the distribution system, which increases power loss and results in neutral potential variation. Compared to the conventional power transformer, the smart transformer (ST) has advantages on the downstream voltage regulation. Thus, this paper proposes a voltage control strategy based on ST to reduce the LV grid neutral current according with EN 50160 imbalanced voltage standard. The proposed control has been validated in the Matlab/Simulink, and the system performance under the proposed control has been simulated under the imbalanced loading profile in a 400 kVA, 10 kV/400 V distribution network. The results prove the proposed control can practically reduce the neutral current.