人工耳廓假体植入术中颞骨定位放置较长假体位置的临床解剖研究

K. Ramkumar, S. Sripriya, C. Sabarigirinathan
{"title":"人工耳廓假体植入术中颞骨定位放置较长假体位置的临床解剖研究","authors":"K. Ramkumar, S. Sripriya, C. Sabarigirinathan","doi":"10.31254/dentistry.2020.5104","DOIUrl":null,"url":null,"abstract":"Aim: To find sites in human temporal bone for placing longer implant Materials & Methods: Dry human skull were procured from the anatomy department. External acoustic meatus(EAM) was taken as reference point from that point five arcs of radius15mm, 20mm,25mm,30mm,35 mm were drawn over the temporal bone. The temporal bone removed from the skull and the bone is removed from the outer most point towards the EAM. The thickness of the bone at 1oClock and 4o Clock position and 8oClock and 11o Clock position over the left and right side of the temporal measured using digital Vernier calliper. The temporal bone is thicker at the 3oClock on the left and 9oClock on the right side. The thickness at the new position also measured. Result: The mean bone thickness at 15mm, 20mm, 25mm ranges from 3.92 to 12.08mm. The mean bone Thickness at the 3oclock and 9 o clock position at the distance of 20mm from EAM ranges from 8.21 to 8.50mm.The Statistical significance within the group were analysed using paired t test and found to be statistical significant at P value less than. 05. Conclusion: The external surface of temporal bone at the 3oClock on the left and 9oClock on the right side denser and thicker. The bone availability is also more favours for placing longer implant.","PeriodicalId":240291,"journal":{"name":"International Journal of Dentistry Research","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of human temporal bone for loacting favourable site to place longer implant for implant retained auricular prosthesis –a clinicoanatomic study\",\"authors\":\"K. Ramkumar, S. Sripriya, C. Sabarigirinathan\",\"doi\":\"10.31254/dentistry.2020.5104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: To find sites in human temporal bone for placing longer implant Materials & Methods: Dry human skull were procured from the anatomy department. External acoustic meatus(EAM) was taken as reference point from that point five arcs of radius15mm, 20mm,25mm,30mm,35 mm were drawn over the temporal bone. The temporal bone removed from the skull and the bone is removed from the outer most point towards the EAM. The thickness of the bone at 1oClock and 4o Clock position and 8oClock and 11o Clock position over the left and right side of the temporal measured using digital Vernier calliper. The temporal bone is thicker at the 3oClock on the left and 9oClock on the right side. The thickness at the new position also measured. Result: The mean bone thickness at 15mm, 20mm, 25mm ranges from 3.92 to 12.08mm. The mean bone Thickness at the 3oclock and 9 o clock position at the distance of 20mm from EAM ranges from 8.21 to 8.50mm.The Statistical significance within the group were analysed using paired t test and found to be statistical significant at P value less than. 05. Conclusion: The external surface of temporal bone at the 3oClock on the left and 9oClock on the right side denser and thicker. The bone availability is also more favours for placing longer implant.\",\"PeriodicalId\":240291,\"journal\":{\"name\":\"International Journal of Dentistry Research\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Dentistry Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31254/dentistry.2020.5104\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Dentistry Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31254/dentistry.2020.5104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:寻找在人颞骨内放置较长种植体的位置。材料与方法:从解剖处获得干颅骨。以外声道(EAM)为参考点,在颞骨上绘制半径为15mm、20mm、25mm、30mm、35mm的5条弧。将颞骨从颅骨上移开,并将骨头从最外侧点移向EAM。使用数字游标卡尺测量颞骨左右两侧在10clock和40clock位置以及8clock和110clock位置的骨厚度。左侧3oClock和右侧9oClock处颞骨较厚。同时测量了新位置的厚度。结果:15mm、20mm、25mm的平均骨厚为3.92 ~ 12.08mm。在距EAM 20mm的3点和9点位置,平均骨厚度为8.21至8.50mm。采用配对t检验分析组内统计学显著性,P值小于。05. 结论:左侧3lock、右侧9lock颞骨外表面密度大、厚度大。骨的可用性也更有利于放置较长的种植体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of human temporal bone for loacting favourable site to place longer implant for implant retained auricular prosthesis –a clinicoanatomic study
Aim: To find sites in human temporal bone for placing longer implant Materials & Methods: Dry human skull were procured from the anatomy department. External acoustic meatus(EAM) was taken as reference point from that point five arcs of radius15mm, 20mm,25mm,30mm,35 mm were drawn over the temporal bone. The temporal bone removed from the skull and the bone is removed from the outer most point towards the EAM. The thickness of the bone at 1oClock and 4o Clock position and 8oClock and 11o Clock position over the left and right side of the temporal measured using digital Vernier calliper. The temporal bone is thicker at the 3oClock on the left and 9oClock on the right side. The thickness at the new position also measured. Result: The mean bone thickness at 15mm, 20mm, 25mm ranges from 3.92 to 12.08mm. The mean bone Thickness at the 3oclock and 9 o clock position at the distance of 20mm from EAM ranges from 8.21 to 8.50mm.The Statistical significance within the group were analysed using paired t test and found to be statistical significant at P value less than. 05. Conclusion: The external surface of temporal bone at the 3oClock on the left and 9oClock on the right side denser and thicker. The bone availability is also more favours for placing longer implant.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信