微电网电能质量调节器

C. N. Bhende, Akhtar Kalam
{"title":"微电网电能质量调节器","authors":"C. N. Bhende, Akhtar Kalam","doi":"10.1109/AUPEC.2013.6725396","DOIUrl":null,"url":null,"abstract":"In this paper, a power quality (PQ) conditioner for microgrid is presented. The main inverter which is associated with distribution generation (DG) and distribution static shunt compensator (DSTATCOM) connected at point of common coupling (PCC) form a PQ conditioner. PQ conditioner of microgrid may be referred as Microgrid Power Quality Conditioner (MPQC). The unbalanced and non-linear load of microgrid is responsible for the flow of unwanted currents through transmission line between microgrid and grid. Hence, the aim of MPQC is to eliminate harmonics from line currents and make them balanced. For this purpose, novel control strategies for MPQC are proposed. Moreover, DSTATCOM supplies the reactive power required by the load locally and hence, neither inverter nor grid supplies the reactive power. Extensive simulation results using MATLAB/SIMULINK established that the performance of the controllers is quite satisfactory for the elimination of PQ problems.","PeriodicalId":121040,"journal":{"name":"2013 Australasian Universities Power Engineering Conference (AUPEC)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Power Quality Conditioner for Microgrid\",\"authors\":\"C. N. Bhende, Akhtar Kalam\",\"doi\":\"10.1109/AUPEC.2013.6725396\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a power quality (PQ) conditioner for microgrid is presented. The main inverter which is associated with distribution generation (DG) and distribution static shunt compensator (DSTATCOM) connected at point of common coupling (PCC) form a PQ conditioner. PQ conditioner of microgrid may be referred as Microgrid Power Quality Conditioner (MPQC). The unbalanced and non-linear load of microgrid is responsible for the flow of unwanted currents through transmission line between microgrid and grid. Hence, the aim of MPQC is to eliminate harmonics from line currents and make them balanced. For this purpose, novel control strategies for MPQC are proposed. Moreover, DSTATCOM supplies the reactive power required by the load locally and hence, neither inverter nor grid supplies the reactive power. Extensive simulation results using MATLAB/SIMULINK established that the performance of the controllers is quite satisfactory for the elimination of PQ problems.\",\"PeriodicalId\":121040,\"journal\":{\"name\":\"2013 Australasian Universities Power Engineering Conference (AUPEC)\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Australasian Universities Power Engineering Conference (AUPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AUPEC.2013.6725396\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Australasian Universities Power Engineering Conference (AUPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AUPEC.2013.6725396","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文介绍了一种微电网电能质量调节器。与配电发电(DG)相关联的主逆变器和连接在共耦合点(PCC)的配电静态并联补偿器(DSTATCOM)构成PQ调节器。微电网PQ调节器可简称为微电网电能质量调节器(MPQC)。微电网的不平衡和非线性负载是造成微电网与电网之间的传输线产生不良电流的主要原因。因此,MPQC的目的是消除线路电流中的谐波并使其平衡。为此,提出了一种新的MPQC控制策略。此外,DSTATCOM在本地提供负载所需的无功功率,因此逆变器和电网都不提供无功功率。利用MATLAB/SIMULINK进行了大量仿真,结果表明,控制器的性能令人满意,可以消除PQ问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power Quality Conditioner for Microgrid
In this paper, a power quality (PQ) conditioner for microgrid is presented. The main inverter which is associated with distribution generation (DG) and distribution static shunt compensator (DSTATCOM) connected at point of common coupling (PCC) form a PQ conditioner. PQ conditioner of microgrid may be referred as Microgrid Power Quality Conditioner (MPQC). The unbalanced and non-linear load of microgrid is responsible for the flow of unwanted currents through transmission line between microgrid and grid. Hence, the aim of MPQC is to eliminate harmonics from line currents and make them balanced. For this purpose, novel control strategies for MPQC are proposed. Moreover, DSTATCOM supplies the reactive power required by the load locally and hence, neither inverter nor grid supplies the reactive power. Extensive simulation results using MATLAB/SIMULINK established that the performance of the controllers is quite satisfactory for the elimination of PQ problems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信