研究线圈匝数对电磁喷油器有效磁能的影响

N. Khoa, Trinh Dac Phong, Nguyen Thanh Vinh, N. Kien
{"title":"研究线圈匝数对电磁喷油器有效磁能的影响","authors":"N. Khoa, Trinh Dac Phong, Nguyen Thanh Vinh, N. Kien","doi":"10.1109/GTSD54989.2022.9989153","DOIUrl":null,"url":null,"abstract":"This paper presents a study the effect of coil turn numbers on the magnetic and effective magnetic energy of a solenoid injector. To achieve this goal, a magnetic injector simulation model is setup based on the Maxwell software. From this simulation software, the researchers are able to investigate the effect of input parameters on the solenoid injector magnetic and effective magnetic energy. Those input parameters are: coil turn numbers, coil cross section area, input current and input voltage. In scope of this research, the effect of coil turn numbers on the injector performance will be completely discussed. The results of the research show that: the coil turn numbers have sensitive effect on solenoid injector magnetic and effective magnetic energy. When the coil turn numbers increase form 40 turn to 80 turn, the injector magnetic increases form 0.167 T t 0.33 T, improved 100%. The injector effective magnetic energy increases form 4.86 KJ/m3 to 19.6 KJ/m3, improved 300%.","PeriodicalId":125445,"journal":{"name":"2022 6th International Conference on Green Technology and Sustainable Development (GTSD)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study the Effect of Coil Turn Numbers on the Effective Magnetic Energy of a Solenoid Injector\",\"authors\":\"N. Khoa, Trinh Dac Phong, Nguyen Thanh Vinh, N. Kien\",\"doi\":\"10.1109/GTSD54989.2022.9989153\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a study the effect of coil turn numbers on the magnetic and effective magnetic energy of a solenoid injector. To achieve this goal, a magnetic injector simulation model is setup based on the Maxwell software. From this simulation software, the researchers are able to investigate the effect of input parameters on the solenoid injector magnetic and effective magnetic energy. Those input parameters are: coil turn numbers, coil cross section area, input current and input voltage. In scope of this research, the effect of coil turn numbers on the injector performance will be completely discussed. The results of the research show that: the coil turn numbers have sensitive effect on solenoid injector magnetic and effective magnetic energy. When the coil turn numbers increase form 40 turn to 80 turn, the injector magnetic increases form 0.167 T t 0.33 T, improved 100%. The injector effective magnetic energy increases form 4.86 KJ/m3 to 19.6 KJ/m3, improved 300%.\",\"PeriodicalId\":125445,\"journal\":{\"name\":\"2022 6th International Conference on Green Technology and Sustainable Development (GTSD)\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 6th International Conference on Green Technology and Sustainable Development (GTSD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GTSD54989.2022.9989153\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 6th International Conference on Green Technology and Sustainable Development (GTSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GTSD54989.2022.9989153","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了线圈匝数对电磁喷油器磁性能和有效磁能的影响。为了实现这一目标,基于Maxwell软件建立了磁性注入器仿真模型。通过该仿真软件,研究人员能够研究输入参数对螺线管喷油器磁性和有效磁能的影响。这些输入参数是:线圈匝数、线圈截面面积、输入电流和输入电压。在本研究的范围内,将全面讨论线圈匝数对喷射器性能的影响。研究结果表明:线圈匝数对电磁喷油器磁场和有效磁能有敏感影响。当线圈匝数从40匝增加到80匝时,注入器磁力从0.167 T增加到0.33 T,提高100%。注入器有效磁能由4.86 KJ/m3提高到19.6 KJ/m3,提高了300%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study the Effect of Coil Turn Numbers on the Effective Magnetic Energy of a Solenoid Injector
This paper presents a study the effect of coil turn numbers on the magnetic and effective magnetic energy of a solenoid injector. To achieve this goal, a magnetic injector simulation model is setup based on the Maxwell software. From this simulation software, the researchers are able to investigate the effect of input parameters on the solenoid injector magnetic and effective magnetic energy. Those input parameters are: coil turn numbers, coil cross section area, input current and input voltage. In scope of this research, the effect of coil turn numbers on the injector performance will be completely discussed. The results of the research show that: the coil turn numbers have sensitive effect on solenoid injector magnetic and effective magnetic energy. When the coil turn numbers increase form 40 turn to 80 turn, the injector magnetic increases form 0.167 T t 0.33 T, improved 100%. The injector effective magnetic energy increases form 4.86 KJ/m3 to 19.6 KJ/m3, improved 300%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信