按照欧洲规范8设计的耦合墙的非线性地震评价

Ivan Mrdak, M. Rakočević
{"title":"按照欧洲规范8设计的耦合墙的非线性地震评价","authors":"Ivan Mrdak, M. Rakočević","doi":"10.5592/co/2crocee.2023.93","DOIUrl":null,"url":null,"abstract":"Experience from previous earthquakes have shown that wall structural systems experience less damage during earthquake compared to frame systems. Wall systems for functional and architectural reasons frequently have openings (windows, doors, elevators, esc.). Wall systems with regularly distributed openings represent efficient system for resisting earthquake loads. Coupling beams connecting the walls, if designed and detailed properly, increase seismic resistance of the building by distribution of inelastic deformations both vertically and in plan. Eurocode 8 introduced set of rules for design and detailing of coupled walls and coupling beams. In order to access performance of coupled walls and beams designed in accordance with EC8, linear and nonlinear analysis of 11 story building was performed. Linear elastic modelling was done using software for linear analysis. The walls and coupling beams were designed and detailed in accordance with the provisions of Eurocode 8, part 1. Nonlinear model and assessment of inelastic response was conducted using Perform 3d CSI software for nonlinear analysis. For the modelling of coupled walls, wall section with fibers is used. The confined constitutive relationship is used for concrete edge elements, and unconfined relationship for concrete for the rest part. The reinforcement constitutive model was defined with bi-linear curve. Coupling beams are modelled using frame elements with shear hinge elements. Deformation capacities of elements was defined in accordance with EC8 provisions. Considering that EC8 doesn’t provide provisions for deformation capacities of diagonally reinforced coupling beams, deformation capacities for these elements is defined in accordance with the provisions of ASCE 41-06 standard. Static nonlinear analysis is performed in accordance with EC8 provisions and deformation capacities of wall elements and coupling beams checked in accordance with the provisions EC8 part 1 and part 3, where applicable. Characteristic results are presented on the end of paper, with conclusions and recommendations.","PeriodicalId":427395,"journal":{"name":"2nd Croatian Conference on Earthquake Engineering ‒ 2CroCEE","volume":"111 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"NONLINEAR SEISMIC ASSESSMENT OF COUPLED WALLS DESIGNED IN ACCORDANCE WITH EUROCODE 8\",\"authors\":\"Ivan Mrdak, M. Rakočević\",\"doi\":\"10.5592/co/2crocee.2023.93\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Experience from previous earthquakes have shown that wall structural systems experience less damage during earthquake compared to frame systems. Wall systems for functional and architectural reasons frequently have openings (windows, doors, elevators, esc.). Wall systems with regularly distributed openings represent efficient system for resisting earthquake loads. Coupling beams connecting the walls, if designed and detailed properly, increase seismic resistance of the building by distribution of inelastic deformations both vertically and in plan. Eurocode 8 introduced set of rules for design and detailing of coupled walls and coupling beams. In order to access performance of coupled walls and beams designed in accordance with EC8, linear and nonlinear analysis of 11 story building was performed. Linear elastic modelling was done using software for linear analysis. The walls and coupling beams were designed and detailed in accordance with the provisions of Eurocode 8, part 1. Nonlinear model and assessment of inelastic response was conducted using Perform 3d CSI software for nonlinear analysis. For the modelling of coupled walls, wall section with fibers is used. The confined constitutive relationship is used for concrete edge elements, and unconfined relationship for concrete for the rest part. The reinforcement constitutive model was defined with bi-linear curve. Coupling beams are modelled using frame elements with shear hinge elements. Deformation capacities of elements was defined in accordance with EC8 provisions. Considering that EC8 doesn’t provide provisions for deformation capacities of diagonally reinforced coupling beams, deformation capacities for these elements is defined in accordance with the provisions of ASCE 41-06 standard. Static nonlinear analysis is performed in accordance with EC8 provisions and deformation capacities of wall elements and coupling beams checked in accordance with the provisions EC8 part 1 and part 3, where applicable. Characteristic results are presented on the end of paper, with conclusions and recommendations.\",\"PeriodicalId\":427395,\"journal\":{\"name\":\"2nd Croatian Conference on Earthquake Engineering ‒ 2CroCEE\",\"volume\":\"111 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2nd Croatian Conference on Earthquake Engineering ‒ 2CroCEE\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5592/co/2crocee.2023.93\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2nd Croatian Conference on Earthquake Engineering ‒ 2CroCEE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5592/co/2crocee.2023.93","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

以往地震的经验表明,与框架体系相比,墙体结构体系在地震中受到的破坏更小。出于功能和建筑原因,墙体系统经常有开口(窗户、门、电梯等)。具有规则分布开口的墙体体系是有效的抗震体系。连接墙壁的耦合梁,如果设计和细节适当,可以通过竖向和平面上的非弹性变形分布来增加建筑物的抗震能力。欧洲规范8引入了一套耦合墙和耦合梁的设计和细节规则。为了了解按照EC8设计的耦合墙和梁的性能,对11层建筑进行了线性和非线性分析。利用线性分析软件进行了线性弹性建模。根据欧洲规范第8部分的规定,对墙壁和连接梁进行了设计和详细说明。采用Perform三维CSI软件进行非线性分析,建立非线性模型并评估非弹性响应。耦合壁面的建模采用带纤维的壁面截面。混凝土边缘单元采用约束本构关系,其余部分采用无约束本构关系。采用双线性曲线定义钢筋本构模型。耦合梁采用带剪力铰单元的框架单元进行建模。根据EC8的规定定义了构件的变形能力。考虑到EC8没有对对角钢筋连接梁的变形能力进行规定,这些构件的变形能力按照ASCE 41-06标准的规定进行定义。根据EC8的规定进行静态非线性分析,并根据EC8第1部分和第3部分的规定检查墙体元件和耦合梁的变形能力。论文最后给出了特征结果,并给出了结论和建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
NONLINEAR SEISMIC ASSESSMENT OF COUPLED WALLS DESIGNED IN ACCORDANCE WITH EUROCODE 8
Experience from previous earthquakes have shown that wall structural systems experience less damage during earthquake compared to frame systems. Wall systems for functional and architectural reasons frequently have openings (windows, doors, elevators, esc.). Wall systems with regularly distributed openings represent efficient system for resisting earthquake loads. Coupling beams connecting the walls, if designed and detailed properly, increase seismic resistance of the building by distribution of inelastic deformations both vertically and in plan. Eurocode 8 introduced set of rules for design and detailing of coupled walls and coupling beams. In order to access performance of coupled walls and beams designed in accordance with EC8, linear and nonlinear analysis of 11 story building was performed. Linear elastic modelling was done using software for linear analysis. The walls and coupling beams were designed and detailed in accordance with the provisions of Eurocode 8, part 1. Nonlinear model and assessment of inelastic response was conducted using Perform 3d CSI software for nonlinear analysis. For the modelling of coupled walls, wall section with fibers is used. The confined constitutive relationship is used for concrete edge elements, and unconfined relationship for concrete for the rest part. The reinforcement constitutive model was defined with bi-linear curve. Coupling beams are modelled using frame elements with shear hinge elements. Deformation capacities of elements was defined in accordance with EC8 provisions. Considering that EC8 doesn’t provide provisions for deformation capacities of diagonally reinforced coupling beams, deformation capacities for these elements is defined in accordance with the provisions of ASCE 41-06 standard. Static nonlinear analysis is performed in accordance with EC8 provisions and deformation capacities of wall elements and coupling beams checked in accordance with the provisions EC8 part 1 and part 3, where applicable. Characteristic results are presented on the end of paper, with conclusions and recommendations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信