{"title":"并网氢燃料电池系统低谐波高效输电的多电平逆变器直流链路控制方法","authors":"Beyzanur Göncü, Ünal Yilmaz","doi":"10.24012/dumf.1293293","DOIUrl":null,"url":null,"abstract":"In grid-connected power generation systems, dc-link voltage control is needed to prevent energy losses, reduce voltage fluctuations and provide a stable energy flow. In addition, control of the power factor via the voltage source inverter is a process that supports the efficient use of the energy produced. Moreover, keeping the total harmonic distortion (THD) of the current injected into the grid in accordance with IEEE-519 harmonic standards (","PeriodicalId":158576,"journal":{"name":"DÜMF Mühendislik Dergisi","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Different DC-Link Control Methods with Multilevel Inverter for Low Harmonic and Efficient Power Transfer in Grid-Tied Hydrogen Fuel Cell Systems\",\"authors\":\"Beyzanur Göncü, Ünal Yilmaz\",\"doi\":\"10.24012/dumf.1293293\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In grid-connected power generation systems, dc-link voltage control is needed to prevent energy losses, reduce voltage fluctuations and provide a stable energy flow. In addition, control of the power factor via the voltage source inverter is a process that supports the efficient use of the energy produced. Moreover, keeping the total harmonic distortion (THD) of the current injected into the grid in accordance with IEEE-519 harmonic standards (\",\"PeriodicalId\":158576,\"journal\":{\"name\":\"DÜMF Mühendislik Dergisi\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DÜMF Mühendislik Dergisi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24012/dumf.1293293\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DÜMF Mühendislik Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24012/dumf.1293293","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Different DC-Link Control Methods with Multilevel Inverter for Low Harmonic and Efficient Power Transfer in Grid-Tied Hydrogen Fuel Cell Systems
In grid-connected power generation systems, dc-link voltage control is needed to prevent energy losses, reduce voltage fluctuations and provide a stable energy flow. In addition, control of the power factor via the voltage source inverter is a process that supports the efficient use of the energy produced. Moreover, keeping the total harmonic distortion (THD) of the current injected into the grid in accordance with IEEE-519 harmonic standards (