{"title":"PT. INDONESIA POWER PGU SURALAYA的电机保护继电器系统通用电气多线中继269 PLUS发动机FORCED FAN dralaya","authors":"Mastiri Mastiri, Desmira Desmira","doi":"10.55606/jurritek.v1i2.278","DOIUrl":null,"url":null,"abstract":"Electrical energy continues to grow over time, power plants with large capacities are the main sources of electricity in Indonesia, one of which is the Steam Power Plant (PLTU). In the field of power plants that use coal always need air during the electricity production process. This study aims 1) to determine the protection management system on the Forced Draft fan motor using GE Multilin 269 Plus, 2) Setting GE Multilin 269 Plus as protection, 3) The results of the protection in the form of Normal Motor, Alarm, and Trip conditions in the accumulation of imbalance (Unbalance) ). The method used is a quantitative research method based on analysis, taking data and then analyzing the data obtained. The results of this quantitative study regarding the Unbalance value or imbalance of the electric motor analyzed resulted in a value of 5.8% for normal conditions, 10.86% for alarm conditions on multilin and 15.50% in trip conditions or the motor had stopped. These values ​​are obtained from the results of calculations comparing negative sequence currents and positive sequence currents (In/Ip). The conclusion obtained is that the GE Multilin 269 Plus protects the electric motor from system damage by using a current sensor and through a setting point that is adjusted to the provisions of NEMA (National Electrical Manufacturers Association) with an unbalance value of more than 15% for trips, more than 10% for alarm conditions and less than 10% under normal conditions","PeriodicalId":224124,"journal":{"name":"JURAL RISET RUMPUN ILMU TEKNIK","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SISTEM MANAJEMEN PROTEKSI MOTOR RELAY GE MULTILINE 269 PLUS PADA MOTOR FORCED DRAFT FAN DI PT. INDONESIA POWER PGU SURALAYA\",\"authors\":\"Mastiri Mastiri, Desmira Desmira\",\"doi\":\"10.55606/jurritek.v1i2.278\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrical energy continues to grow over time, power plants with large capacities are the main sources of electricity in Indonesia, one of which is the Steam Power Plant (PLTU). In the field of power plants that use coal always need air during the electricity production process. This study aims 1) to determine the protection management system on the Forced Draft fan motor using GE Multilin 269 Plus, 2) Setting GE Multilin 269 Plus as protection, 3) The results of the protection in the form of Normal Motor, Alarm, and Trip conditions in the accumulation of imbalance (Unbalance) ). The method used is a quantitative research method based on analysis, taking data and then analyzing the data obtained. The results of this quantitative study regarding the Unbalance value or imbalance of the electric motor analyzed resulted in a value of 5.8% for normal conditions, 10.86% for alarm conditions on multilin and 15.50% in trip conditions or the motor had stopped. These values ​​are obtained from the results of calculations comparing negative sequence currents and positive sequence currents (In/Ip). The conclusion obtained is that the GE Multilin 269 Plus protects the electric motor from system damage by using a current sensor and through a setting point that is adjusted to the provisions of NEMA (National Electrical Manufacturers Association) with an unbalance value of more than 15% for trips, more than 10% for alarm conditions and less than 10% under normal conditions\",\"PeriodicalId\":224124,\"journal\":{\"name\":\"JURAL RISET RUMPUN ILMU TEKNIK\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JURAL RISET RUMPUN ILMU TEKNIK\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55606/jurritek.v1i2.278\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JURAL RISET RUMPUN ILMU TEKNIK","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55606/jurritek.v1i2.278","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着时间的推移,电能持续增长,大容量的发电厂是印度尼西亚电力的主要来源,其中之一是蒸汽发电厂(PLTU)。燃煤电厂在发电过程中始终需要空气。本研究的目的是:1)确定采用GE Multilin 269 Plus对强制风机电机的保护管理系统,2)设置GE Multilin 269 Plus作为保护,3)在积累不平衡(Unbalance)的情况下,以电机正常、报警和跳闸的形式进行保护的结果。使用的方法是基于分析的定量研究方法,获取数据,然后分析得到的数据。对电机的不平衡值或不平衡分析的定量研究结果表明,正常情况下的不平衡值为5.8%,multilin报警情况下的不平衡值为10.86%,跳闸或电机停止情况下的不平衡值为15.50%。这些值是从比较负序电流和正序电流(In/Ip)的计算结果中获得的。得出的结论是,GE Multilin 269 Plus通过使用电流传感器和调整到NEMA(国家电气制造商协会)规定的设置点来保护电动机免受系统损坏,该设置点在跳闸时的不平衡值大于15%,在报警条件下大于10%,在正常情况下小于10%
本文章由计算机程序翻译,如有差异,请以英文原文为准。
SISTEM MANAJEMEN PROTEKSI MOTOR RELAY GE MULTILINE 269 PLUS PADA MOTOR FORCED DRAFT FAN DI PT. INDONESIA POWER PGU SURALAYA
Electrical energy continues to grow over time, power plants with large capacities are the main sources of electricity in Indonesia, one of which is the Steam Power Plant (PLTU). In the field of power plants that use coal always need air during the electricity production process. This study aims 1) to determine the protection management system on the Forced Draft fan motor using GE Multilin 269 Plus, 2) Setting GE Multilin 269 Plus as protection, 3) The results of the protection in the form of Normal Motor, Alarm, and Trip conditions in the accumulation of imbalance (Unbalance) ). The method used is a quantitative research method based on analysis, taking data and then analyzing the data obtained. The results of this quantitative study regarding the Unbalance value or imbalance of the electric motor analyzed resulted in a value of 5.8% for normal conditions, 10.86% for alarm conditions on multilin and 15.50% in trip conditions or the motor had stopped. These values ​​are obtained from the results of calculations comparing negative sequence currents and positive sequence currents (In/Ip). The conclusion obtained is that the GE Multilin 269 Plus protects the electric motor from system damage by using a current sensor and through a setting point that is adjusted to the provisions of NEMA (National Electrical Manufacturers Association) with an unbalance value of more than 15% for trips, more than 10% for alarm conditions and less than 10% under normal conditions
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信