考虑可变可再生能源并网和增强柔性对电网稳定性影响的印尼典型岛屿微电网可再生能源渗透极限研究

K. M. Banjar-Nahor, L. Garbuio, V. Debusschere, N. Hadjsaid, T. Pham, N. Sinisuka
{"title":"考虑可变可再生能源并网和增强柔性对电网稳定性影响的印尼典型岛屿微电网可再生能源渗透极限研究","authors":"K. M. Banjar-Nahor, L. Garbuio, V. Debusschere, N. Hadjsaid, T. Pham, N. Sinisuka","doi":"10.1109/ISGTEurope.2018.8571673","DOIUrl":null,"url":null,"abstract":"This study assesses the impacts of variable renewabIes and the use of flexibility on frequency, voltage, and angle stability in a typical isolated microgrid in Indonesia. The simulations in Power Factory have illustrated the flexibility options and the stability behavior evolution, considering a parametric study on the shares of inverter-based variable renewable energy resources. The 10% limit of variable renewabIes in Indonesian microgrids is also discussed and proven to be rather pessimistic, as this research reaches the instantaneous penetration rate varying from 0% to 31.3% in the considered scenarios.","PeriodicalId":302863,"journal":{"name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Study on Renewable Penetration Limits in a Typical Indonesian Islanded Microgrid Considering the Impact of Variable Renewables Integration and the Empowering Flexibility on Grid Stability\",\"authors\":\"K. M. Banjar-Nahor, L. Garbuio, V. Debusschere, N. Hadjsaid, T. Pham, N. Sinisuka\",\"doi\":\"10.1109/ISGTEurope.2018.8571673\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study assesses the impacts of variable renewabIes and the use of flexibility on frequency, voltage, and angle stability in a typical isolated microgrid in Indonesia. The simulations in Power Factory have illustrated the flexibility options and the stability behavior evolution, considering a parametric study on the shares of inverter-based variable renewable energy resources. The 10% limit of variable renewabIes in Indonesian microgrids is also discussed and proven to be rather pessimistic, as this research reaches the instantaneous penetration rate varying from 0% to 31.3% in the considered scenarios.\",\"PeriodicalId\":302863,\"journal\":{\"name\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2018.8571673\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2018.8571673","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本研究评估了印度尼西亚典型孤立微电网中可变可再生能源和灵活性对频率、电压和角度稳定性的影响。通过电厂的仿真,说明了考虑逆变器可变可再生能源份额参数化研究的柔性选择和稳定性行为演化。本文还讨论了印尼微电网10%可变可再生能源的限制,并证明了这一限制相当悲观,因为本研究得出的瞬时渗透率在考虑的情景中从0%到31.3%不等。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study on Renewable Penetration Limits in a Typical Indonesian Islanded Microgrid Considering the Impact of Variable Renewables Integration and the Empowering Flexibility on Grid Stability
This study assesses the impacts of variable renewabIes and the use of flexibility on frequency, voltage, and angle stability in a typical isolated microgrid in Indonesia. The simulations in Power Factory have illustrated the flexibility options and the stability behavior evolution, considering a parametric study on the shares of inverter-based variable renewable energy resources. The 10% limit of variable renewabIes in Indonesian microgrids is also discussed and proven to be rather pessimistic, as this research reaches the instantaneous penetration rate varying from 0% to 31.3% in the considered scenarios.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信