提高微水电厂稳定性的频率和电压控制器设计

U. K. John, Asinge W. Jack, Musa Nasaaga
{"title":"提高微水电厂稳定性的频率和电压控制器设计","authors":"U. K. John, Asinge W. Jack, Musa Nasaaga","doi":"10.1109/AICT47866.2019.8981777","DOIUrl":null,"url":null,"abstract":"This research work uses Fuzzy Logic Controller (FLC) in order to contribute to Micro Hydro Power Plants (MHPPs) stability and dynamic performance improvement. Its effectiveness is shown through a comparative analysis to Conventional Controllers (CC) simulated in Matlab/Simulink 2018a. Both controllers are subjected to dynamic performance tests in order to evaluate their respective transient, performance and robustness responses in a designed MHPP. Results reveal that FLC provides an average reduction of 4.91s and 14.11% respectively in response time and overshoot. These results show that FLC has significantly improved the stability and the dynamic performance of the MHPP.","PeriodicalId":329473,"journal":{"name":"2019 IEEE 13th International Conference on Application of Information and Communication Technologies (AICT)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design of Frequency and Voltage Controller for Stability Improvement in a Micro Hydro Power Plant\",\"authors\":\"U. K. John, Asinge W. Jack, Musa Nasaaga\",\"doi\":\"10.1109/AICT47866.2019.8981777\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research work uses Fuzzy Logic Controller (FLC) in order to contribute to Micro Hydro Power Plants (MHPPs) stability and dynamic performance improvement. Its effectiveness is shown through a comparative analysis to Conventional Controllers (CC) simulated in Matlab/Simulink 2018a. Both controllers are subjected to dynamic performance tests in order to evaluate their respective transient, performance and robustness responses in a designed MHPP. Results reveal that FLC provides an average reduction of 4.91s and 14.11% respectively in response time and overshoot. These results show that FLC has significantly improved the stability and the dynamic performance of the MHPP.\",\"PeriodicalId\":329473,\"journal\":{\"name\":\"2019 IEEE 13th International Conference on Application of Information and Communication Technologies (AICT)\",\"volume\":\"78 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 13th International Conference on Application of Information and Communication Technologies (AICT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AICT47866.2019.8981777\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 13th International Conference on Application of Information and Communication Technologies (AICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AICT47866.2019.8981777","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究采用模糊逻辑控制器(FLC)来提高微水电厂的稳定性和动态性能。通过与Matlab/Simulink 2018a中仿真的传统控制器(CC)进行对比分析,证明了其有效性。在设计的MHPP中,两个控制器都进行了动态性能测试,以评估它们各自的瞬态、性能和鲁棒性响应。结果表明,FLC在响应时间和超调量上分别平均降低了4.91秒和14.11%。结果表明,FLC显著提高了MHPP的稳定性和动态性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of Frequency and Voltage Controller for Stability Improvement in a Micro Hydro Power Plant
This research work uses Fuzzy Logic Controller (FLC) in order to contribute to Micro Hydro Power Plants (MHPPs) stability and dynamic performance improvement. Its effectiveness is shown through a comparative analysis to Conventional Controllers (CC) simulated in Matlab/Simulink 2018a. Both controllers are subjected to dynamic performance tests in order to evaluate their respective transient, performance and robustness responses in a designed MHPP. Results reveal that FLC provides an average reduction of 4.91s and 14.11% respectively in response time and overshoot. These results show that FLC has significantly improved the stability and the dynamic performance of the MHPP.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信