Sukhyanti Kerai, Upasana Singh, Vineet Manchanda, K. Saxena
{"title":"柔性金属气管插管对气道阻塞的持续威胁","authors":"Sukhyanti Kerai, Upasana Singh, Vineet Manchanda, K. Saxena","doi":"10.4103/jica.jica_25_22","DOIUrl":null,"url":null,"abstract":"Flexometallic endotracheal tubes (ETT) are preferred over standard Polyvinyl Chloride ETTs in cases where intraoperatively there is limited airway access to the anaesthesiologist. As they are comparatively expensive, it is common practice to reuse them after sterilization. Here we describe a case where a flexometallic ETT was used in a case of tonsillectomy after a through visual inspection to rule out any structural deformity. Intraoperatively ETT itself led to airway obstruction mimicking bronchospasm.","PeriodicalId":361779,"journal":{"name":"Journal of Indian College of Anaesthesiologists","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Incessant menace of airway obstruction with flexometallic endotracheal tube\",\"authors\":\"Sukhyanti Kerai, Upasana Singh, Vineet Manchanda, K. Saxena\",\"doi\":\"10.4103/jica.jica_25_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Flexometallic endotracheal tubes (ETT) are preferred over standard Polyvinyl Chloride ETTs in cases where intraoperatively there is limited airway access to the anaesthesiologist. As they are comparatively expensive, it is common practice to reuse them after sterilization. Here we describe a case where a flexometallic ETT was used in a case of tonsillectomy after a through visual inspection to rule out any structural deformity. Intraoperatively ETT itself led to airway obstruction mimicking bronchospasm.\",\"PeriodicalId\":361779,\"journal\":{\"name\":\"Journal of Indian College of Anaesthesiologists\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian College of Anaesthesiologists\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jica.jica_25_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian College of Anaesthesiologists","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jica.jica_25_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Incessant menace of airway obstruction with flexometallic endotracheal tube
Flexometallic endotracheal tubes (ETT) are preferred over standard Polyvinyl Chloride ETTs in cases where intraoperatively there is limited airway access to the anaesthesiologist. As they are comparatively expensive, it is common practice to reuse them after sterilization. Here we describe a case where a flexometallic ETT was used in a case of tonsillectomy after a through visual inspection to rule out any structural deformity. Intraoperatively ETT itself led to airway obstruction mimicking bronchospasm.