{"title":"在整个范围内校准的高精度绝对激光功率计","authors":"N. Miron, G. Korony, V. Velculescu","doi":"10.1109/CPEM.1994.333223","DOIUrl":null,"url":null,"abstract":"The main contribution to this laser powermeter is the capability of its detector to be electrically calibrated over the whole measuring range (0...100 W), with an accuracy better than 1%. This allows an improved accuracy in determining the second-order polynomial coefficients describing thermocouple electric response.<<ETX>>","PeriodicalId":388647,"journal":{"name":"Proceedings of Conference on Precision Electromagnetic Measurements Digest","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High accuracy absolute laser powermeter calibrated over the whole range\",\"authors\":\"N. Miron, G. Korony, V. Velculescu\",\"doi\":\"10.1109/CPEM.1994.333223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main contribution to this laser powermeter is the capability of its detector to be electrically calibrated over the whole measuring range (0...100 W), with an accuracy better than 1%. This allows an improved accuracy in determining the second-order polynomial coefficients describing thermocouple electric response.<<ETX>>\",\"PeriodicalId\":388647,\"journal\":{\"name\":\"Proceedings of Conference on Precision Electromagnetic Measurements Digest\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Conference on Precision Electromagnetic Measurements Digest\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.1994.333223\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Conference on Precision Electromagnetic Measurements Digest","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.1994.333223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High accuracy absolute laser powermeter calibrated over the whole range
The main contribution to this laser powermeter is the capability of its detector to be electrically calibrated over the whole measuring range (0...100 W), with an accuracy better than 1%. This allows an improved accuracy in determining the second-order polynomial coefficients describing thermocouple electric response.<>