航空航天电磁继电器长期贮存拾取时间退化建模研究

Zhao-Bin Wang, Shang Shang, Xiaoyi Huang, G. Zhai, Wenhua Chen
{"title":"航空航天电磁继电器长期贮存拾取时间退化建模研究","authors":"Zhao-Bin Wang, Shang Shang, Xiaoyi Huang, G. Zhai, Wenhua Chen","doi":"10.1109/HOLM.2015.7355094","DOIUrl":null,"url":null,"abstract":"The storage degradation test system for aerospace electromagnetic relay (EMR) is designed, which uses FPGA and ARM SCM architecture as system's hardware core. The degradation data rule of pick-up time parameters for aerospace EMR is tested. And the variation law of pick-up time changing with time is obtained. The change of pick-up time is analyzed and verified, which is mainly caused by reeds reaction occurred relaxation. Then, pick-up time and reed reaction exists the approximate linear relationship was found. So, the pick-up time can characterize the degradation of reed relaxation. The storage degradation model of pick-up time is estimated through regression theory. The research results in this paper provide the necessary theoretical method and basis for studying storage reliability and life prediction of the aerospace EMR.","PeriodicalId":448541,"journal":{"name":"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Research on degradation modeling of pick-up time for aerospace electromagnetic relay in long-term stockpile\",\"authors\":\"Zhao-Bin Wang, Shang Shang, Xiaoyi Huang, G. Zhai, Wenhua Chen\",\"doi\":\"10.1109/HOLM.2015.7355094\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The storage degradation test system for aerospace electromagnetic relay (EMR) is designed, which uses FPGA and ARM SCM architecture as system's hardware core. The degradation data rule of pick-up time parameters for aerospace EMR is tested. And the variation law of pick-up time changing with time is obtained. The change of pick-up time is analyzed and verified, which is mainly caused by reeds reaction occurred relaxation. Then, pick-up time and reed reaction exists the approximate linear relationship was found. So, the pick-up time can characterize the degradation of reed relaxation. The storage degradation model of pick-up time is estimated through regression theory. The research results in this paper provide the necessary theoretical method and basis for studying storage reliability and life prediction of the aerospace EMR.\",\"PeriodicalId\":448541,\"journal\":{\"name\":\"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)\",\"volume\":\"78 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.2015.7355094\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2015.7355094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

设计了以FPGA和ARM单片机架构为硬件核心的航天电磁继电器(EMR)存储退化测试系统。测试了航空EMR的拾取时间参数的退化数据规律。得到了采集时间随时间的变化规律。分析并验证了提取时间的变化,主要是芦苇反应发生松弛引起的。结果表明,吸附时间与簧片反应存在近似的线性关系。因此,拾取时间可以表征簧片松弛的退化。利用回归理论估计了取货时间的存储退化模型。本文的研究成果为研究航空电磁雷达的存储可靠性和寿命预测提供了必要的理论方法和依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on degradation modeling of pick-up time for aerospace electromagnetic relay in long-term stockpile
The storage degradation test system for aerospace electromagnetic relay (EMR) is designed, which uses FPGA and ARM SCM architecture as system's hardware core. The degradation data rule of pick-up time parameters for aerospace EMR is tested. And the variation law of pick-up time changing with time is obtained. The change of pick-up time is analyzed and verified, which is mainly caused by reeds reaction occurred relaxation. Then, pick-up time and reed reaction exists the approximate linear relationship was found. So, the pick-up time can characterize the degradation of reed relaxation. The storage degradation model of pick-up time is estimated through regression theory. The research results in this paper provide the necessary theoretical method and basis for studying storage reliability and life prediction of the aerospace EMR.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信