{"title":"配电系统中AMB状态估计器的统计一致性评估","authors":"M. D. de Almeida, Rafael Schincariol, L. Ochoa","doi":"10.1109/ISGT-LA.2015.7381220","DOIUrl":null,"url":null,"abstract":"In this paper the statistical consistency of the single-phase Admittance Matrix-Based State Estimator (AMB SE) originally proposed for distribution systems is for the first time assessed and compared to that of the widely used Traditional SE (TSE). The AMB SE is an interesting alternative for distribution systems given the use of a constant Gain matrix, thus simplifying its implementation and significantly reducing the computational time. However, it is crucial to statistically assess its consistency so as to ensure estimated values and variances (outputs) are in agreement with the specified measurements and variances (inputs). This is carried out using a Monte Carlo analysis and a generic 16-bus UK distribution system. Despite the conversion from actual to equivalent measurements required by the AMB SE, as well as the approximations regarding the variances of the equivalent measurements, the results demonstrate that the single-phase AMB SE is as consistent and precise as the TSE.","PeriodicalId":345318,"journal":{"name":"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)","volume":"9 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Assessing the statistical consistency of the AMB State Estimator in distribution systems\",\"authors\":\"M. D. de Almeida, Rafael Schincariol, L. Ochoa\",\"doi\":\"10.1109/ISGT-LA.2015.7381220\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper the statistical consistency of the single-phase Admittance Matrix-Based State Estimator (AMB SE) originally proposed for distribution systems is for the first time assessed and compared to that of the widely used Traditional SE (TSE). The AMB SE is an interesting alternative for distribution systems given the use of a constant Gain matrix, thus simplifying its implementation and significantly reducing the computational time. However, it is crucial to statistically assess its consistency so as to ensure estimated values and variances (outputs) are in agreement with the specified measurements and variances (inputs). This is carried out using a Monte Carlo analysis and a generic 16-bus UK distribution system. Despite the conversion from actual to equivalent measurements required by the AMB SE, as well as the approximations regarding the variances of the equivalent measurements, the results demonstrate that the single-phase AMB SE is as consistent and precise as the TSE.\",\"PeriodicalId\":345318,\"journal\":{\"name\":\"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)\",\"volume\":\"9 4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGT-LA.2015.7381220\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-LA.2015.7381220","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文首次对基于单相导纳矩阵的配电系统状态估计器(AMB SE)的统计一致性进行了评估,并与广泛使用的传统状态估计器(TSE)进行了比较。对于使用恒定增益矩阵的配电系统来说,AMB SE是一个有趣的替代方案,从而简化了其实现并显着减少了计算时间。然而,至关重要的是统计评估其一致性,以确保估计值和方差(输出)与指定的测量和方差(输入)一致。这是使用蒙特卡罗分析和通用的16总线英国分配系统进行的。尽管AMB - SE需要将实际测量值转换为等效测量值,并对等效测量值的方差进行近似,但结果表明,单相AMB - SE与TSE一样一致和精确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessing the statistical consistency of the AMB State Estimator in distribution systems
In this paper the statistical consistency of the single-phase Admittance Matrix-Based State Estimator (AMB SE) originally proposed for distribution systems is for the first time assessed and compared to that of the widely used Traditional SE (TSE). The AMB SE is an interesting alternative for distribution systems given the use of a constant Gain matrix, thus simplifying its implementation and significantly reducing the computational time. However, it is crucial to statistically assess its consistency so as to ensure estimated values and variances (outputs) are in agreement with the specified measurements and variances (inputs). This is carried out using a Monte Carlo analysis and a generic 16-bus UK distribution system. Despite the conversion from actual to equivalent measurements required by the AMB SE, as well as the approximations regarding the variances of the equivalent measurements, the results demonstrate that the single-phase AMB SE is as consistent and precise as the TSE.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信