用于现场溶解氧测量的穿透微电极传感器

Jin-hwan Lee, Tae-Sun Lim, I. Papautsky
{"title":"用于现场溶解氧测量的穿透微电极传感器","authors":"Jin-hwan Lee, Tae-Sun Lim, I. Papautsky","doi":"10.1109/ICSENS.2007.355889","DOIUrl":null,"url":null,"abstract":"This paper describes a new penetrating micro-electrode array (MEA) sensor for in situ measurements of dissolved oxygen (DO) in bioapplications. The sensor was fabricated using an HF-based etching technique, with a polymerized polypyrrole layer as an insulator. The sensor area was formed by a gold layer inside a 1.7 mum recess at the tip of each microelectrode. Electrochemical performance of these DO MEAs was fully characterized by measuring DO of saline solutions with a Ag/AgCl reference electrode. The DO MEAs exhibited a rapid and linear response in the 0-9 mg/L (0-21% O2) range. These new sensors are able to penetrate samples in order to perform measurements, and are ideally suited for in situ operations due to their small size.","PeriodicalId":233838,"journal":{"name":"2006 5th IEEE Conference on Sensors","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Penetrating Microelectrode Sensor for In Situ Dissolved Oxygen Measurements\",\"authors\":\"Jin-hwan Lee, Tae-Sun Lim, I. Papautsky\",\"doi\":\"10.1109/ICSENS.2007.355889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a new penetrating micro-electrode array (MEA) sensor for in situ measurements of dissolved oxygen (DO) in bioapplications. The sensor was fabricated using an HF-based etching technique, with a polymerized polypyrrole layer as an insulator. The sensor area was formed by a gold layer inside a 1.7 mum recess at the tip of each microelectrode. Electrochemical performance of these DO MEAs was fully characterized by measuring DO of saline solutions with a Ag/AgCl reference electrode. The DO MEAs exhibited a rapid and linear response in the 0-9 mg/L (0-21% O2) range. These new sensors are able to penetrate samples in order to perform measurements, and are ideally suited for in situ operations due to their small size.\",\"PeriodicalId\":233838,\"journal\":{\"name\":\"2006 5th IEEE Conference on Sensors\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 5th IEEE Conference on Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2007.355889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 5th IEEE Conference on Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2007.355889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种用于生物领域溶解氧(DO)原位测量的新型穿透式微电极阵列(MEA)传感器。该传感器采用基于高频的蚀刻技术,以聚合聚吡咯层作为绝缘体。传感器区域由每个微电极顶端1.7微米凹槽内的金层形成。用Ag/AgCl参比电极测量盐溶液的DO,充分表征了这些DO MEAs的电化学性能。在0 ~ 9 mg/L (0 ~ 21% O2)范围内,DO MEAs具有快速的线性响应。这些新型传感器能够穿透样品进行测量,并且由于其体积小,非常适合于原位操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Penetrating Microelectrode Sensor for In Situ Dissolved Oxygen Measurements
This paper describes a new penetrating micro-electrode array (MEA) sensor for in situ measurements of dissolved oxygen (DO) in bioapplications. The sensor was fabricated using an HF-based etching technique, with a polymerized polypyrrole layer as an insulator. The sensor area was formed by a gold layer inside a 1.7 mum recess at the tip of each microelectrode. Electrochemical performance of these DO MEAs was fully characterized by measuring DO of saline solutions with a Ag/AgCl reference electrode. The DO MEAs exhibited a rapid and linear response in the 0-9 mg/L (0-21% O2) range. These new sensors are able to penetrate samples in order to perform measurements, and are ideally suited for in situ operations due to their small size.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信