{"title":"用于现场溶解氧测量的穿透微电极传感器","authors":"Jin-hwan Lee, Tae-Sun Lim, I. Papautsky","doi":"10.1109/ICSENS.2007.355889","DOIUrl":null,"url":null,"abstract":"This paper describes a new penetrating micro-electrode array (MEA) sensor for in situ measurements of dissolved oxygen (DO) in bioapplications. The sensor was fabricated using an HF-based etching technique, with a polymerized polypyrrole layer as an insulator. The sensor area was formed by a gold layer inside a 1.7 mum recess at the tip of each microelectrode. Electrochemical performance of these DO MEAs was fully characterized by measuring DO of saline solutions with a Ag/AgCl reference electrode. The DO MEAs exhibited a rapid and linear response in the 0-9 mg/L (0-21% O2) range. These new sensors are able to penetrate samples in order to perform measurements, and are ideally suited for in situ operations due to their small size.","PeriodicalId":233838,"journal":{"name":"2006 5th IEEE Conference on Sensors","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Penetrating Microelectrode Sensor for In Situ Dissolved Oxygen Measurements\",\"authors\":\"Jin-hwan Lee, Tae-Sun Lim, I. Papautsky\",\"doi\":\"10.1109/ICSENS.2007.355889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a new penetrating micro-electrode array (MEA) sensor for in situ measurements of dissolved oxygen (DO) in bioapplications. The sensor was fabricated using an HF-based etching technique, with a polymerized polypyrrole layer as an insulator. The sensor area was formed by a gold layer inside a 1.7 mum recess at the tip of each microelectrode. Electrochemical performance of these DO MEAs was fully characterized by measuring DO of saline solutions with a Ag/AgCl reference electrode. The DO MEAs exhibited a rapid and linear response in the 0-9 mg/L (0-21% O2) range. These new sensors are able to penetrate samples in order to perform measurements, and are ideally suited for in situ operations due to their small size.\",\"PeriodicalId\":233838,\"journal\":{\"name\":\"2006 5th IEEE Conference on Sensors\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 5th IEEE Conference on Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2007.355889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 5th IEEE Conference on Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2007.355889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Penetrating Microelectrode Sensor for In Situ Dissolved Oxygen Measurements
This paper describes a new penetrating micro-electrode array (MEA) sensor for in situ measurements of dissolved oxygen (DO) in bioapplications. The sensor was fabricated using an HF-based etching technique, with a polymerized polypyrrole layer as an insulator. The sensor area was formed by a gold layer inside a 1.7 mum recess at the tip of each microelectrode. Electrochemical performance of these DO MEAs was fully characterized by measuring DO of saline solutions with a Ag/AgCl reference electrode. The DO MEAs exhibited a rapid and linear response in the 0-9 mg/L (0-21% O2) range. These new sensors are able to penetrate samples in order to perform measurements, and are ideally suited for in situ operations due to their small size.