基于支路电流的配电系统三相状态估计改进算法

Shouxiang Wang, Xiaokun Cui, Zuyi Li, M. Shahidehpour
{"title":"基于支路电流的配电系统三相状态估计改进算法","authors":"Shouxiang Wang, Xiaokun Cui, Zuyi Li, M. Shahidehpour","doi":"10.1109/ISGT-ASIA.2012.6303371","DOIUrl":null,"url":null,"abstract":"The penetration of distributed generations (DGs) in distribution system has been steadily increasing. This paper develops and tests a three-phase-based state estimation algorithm for distribution system with DGs. This algorithm is based on branch currents. The amplitudes and phase angles of branch currents are selected as state variables. A proper change of measurements enables the three-phase distribution system to be decoupled and results in better performance. In addition, DGs are classified into four types and treated as real-time measurements with different information. Different methods are applied to deal with different types of DGs in the state estimation. The proposed algorithm is tested and validated using the IEEE 13-node test distribution system. The impact of different types and different locations of the DGs are studied.","PeriodicalId":330758,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies","volume":"08 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"An improved branch current-based three-phase state estimation algorithm for distribution systems with DGs\",\"authors\":\"Shouxiang Wang, Xiaokun Cui, Zuyi Li, M. Shahidehpour\",\"doi\":\"10.1109/ISGT-ASIA.2012.6303371\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The penetration of distributed generations (DGs) in distribution system has been steadily increasing. This paper develops and tests a three-phase-based state estimation algorithm for distribution system with DGs. This algorithm is based on branch currents. The amplitudes and phase angles of branch currents are selected as state variables. A proper change of measurements enables the three-phase distribution system to be decoupled and results in better performance. In addition, DGs are classified into four types and treated as real-time measurements with different information. Different methods are applied to deal with different types of DGs in the state estimation. The proposed algorithm is tested and validated using the IEEE 13-node test distribution system. The impact of different types and different locations of the DGs are studied.\",\"PeriodicalId\":330758,\"journal\":{\"name\":\"IEEE PES Innovative Smart Grid Technologies\",\"volume\":\"08 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE PES Innovative Smart Grid Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGT-ASIA.2012.6303371\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2012.6303371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

分布式代在配电系统中的应用日益广泛。本文开发并测试了一种基于三相的分布式配电系统状态估计算法。该算法基于支路电流。选取支路电流的幅值和相角作为状态变量。适当改变测量值可以使三相配电系统解耦,从而获得更好的性能。此外,将DGs分为四种类型,并将其视为具有不同信息的实时测量。在状态估计中,采用不同的方法处理不同类型的dg。采用IEEE 13节点测试分配系统对该算法进行了测试和验证。研究了不同类型和不同位置的DGs的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An improved branch current-based three-phase state estimation algorithm for distribution systems with DGs
The penetration of distributed generations (DGs) in distribution system has been steadily increasing. This paper develops and tests a three-phase-based state estimation algorithm for distribution system with DGs. This algorithm is based on branch currents. The amplitudes and phase angles of branch currents are selected as state variables. A proper change of measurements enables the three-phase distribution system to be decoupled and results in better performance. In addition, DGs are classified into four types and treated as real-time measurements with different information. Different methods are applied to deal with different types of DGs in the state estimation. The proposed algorithm is tested and validated using the IEEE 13-node test distribution system. The impact of different types and different locations of the DGs are studied.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信