主动式和被动式电池充电系统无重叠绕组永磁风力发电机的设计优化与比较

C. Labuschagne, M. Kamper
{"title":"主动式和被动式电池充电系统无重叠绕组永磁风力发电机的设计优化与比较","authors":"C. Labuschagne, M. Kamper","doi":"10.1109/ICELMACH.2018.8506821","DOIUrl":null,"url":null,"abstract":"In this paper a comparative study of a small-scale turbine-specific designed non-overlap winding permanent magnet (PM) synchronous wind generator for passive- and active battery charging system is done. The comparative study is based on the optimum designs of the generators with the same power and efficiency performance. Both wind generator systems are described and the methods used in the design optimisation process to generate sufficient performance are discussed. The main comparisons between the generators are the active mass and PM mass. It is shown amongst others that the generator for the widely-industry-used passive system uses more than three times the amount of magnet material than the generator for the active system.","PeriodicalId":292261,"journal":{"name":"2018 XIII International Conference on Electrical Machines (ICEM)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Design Optimisation and Comparison of Non-overlap Winding PM Wind Generators for Active and Passive Battery Charging Systems\",\"authors\":\"C. Labuschagne, M. Kamper\",\"doi\":\"10.1109/ICELMACH.2018.8506821\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a comparative study of a small-scale turbine-specific designed non-overlap winding permanent magnet (PM) synchronous wind generator for passive- and active battery charging system is done. The comparative study is based on the optimum designs of the generators with the same power and efficiency performance. Both wind generator systems are described and the methods used in the design optimisation process to generate sufficient performance are discussed. The main comparisons between the generators are the active mass and PM mass. It is shown amongst others that the generator for the widely-industry-used passive system uses more than three times the amount of magnet material than the generator for the active system.\",\"PeriodicalId\":292261,\"journal\":{\"name\":\"2018 XIII International Conference on Electrical Machines (ICEM)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 XIII International Conference on Electrical Machines (ICEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2018.8506821\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 XIII International Conference on Electrical Machines (ICEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2018.8506821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文对专用于蓄电池无源和有源充电系统的小型无重叠绕组永磁同步风力发电机进行了对比研究。对比研究是基于相同功率和效率性能的发电机的优化设计。描述了两种风力发电机系统,并讨论了在设计优化过程中使用的方法,以产生足够的性能。发电机之间的主要比较是有效质量和PM质量。除其他外,它还表明,用于广泛工业使用的无源系统的发电机使用的磁铁材料量是用于有源系统的发电机的三倍以上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design Optimisation and Comparison of Non-overlap Winding PM Wind Generators for Active and Passive Battery Charging Systems
In this paper a comparative study of a small-scale turbine-specific designed non-overlap winding permanent magnet (PM) synchronous wind generator for passive- and active battery charging system is done. The comparative study is based on the optimum designs of the generators with the same power and efficiency performance. Both wind generator systems are described and the methods used in the design optimisation process to generate sufficient performance are discussed. The main comparisons between the generators are the active mass and PM mass. It is shown amongst others that the generator for the widely-industry-used passive system uses more than three times the amount of magnet material than the generator for the active system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信