{"title":"油田变电站供电系统无功补偿优化","authors":"Y. Konovalov, D. Nurbosynov","doi":"10.1109/ICIEAM.2017.8076228","DOIUrl":null,"url":null,"abstract":"This paper describes reactive power compensation regimes at the level of the oil field electrical substation of the oil and gas production enterprise in terms of active power losses minimization in the feed lines and transformers using local and centralized reactive power sources as well as electrotechnical complexes equipped with synchronous motors. The studies are carried out for a typical oil field electrical substation to determine the most economical mode of the reactive power compensation regime. The following values are determined during the calculations: voltages in the given points of the circuit, voltage drops in the branches of the circuit, currents in the branches, active and reactive power losses in the branches of the circuit and total power losses. Analysis of the obtained results has demonstrated that the optimal regime for the generalized circuit at the oil field electrical substation, in terms of energy saving in feed lines and power transformers, is the overcompensation regime by 30…40 % on the 6.3 kV side. This regime can be achieved by means of the reservoir pressure maintenance system synchronous motors transition to the regime of the reactive power generation. The results of the oil and gas production enterprise certification show that the majority of them have the available reactive power of the synchronous motors which makes it possible to ensure the given regime on the buses of the oil field electrical substation.","PeriodicalId":428982,"journal":{"name":"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Optimization of power supply system reactive power compensation at the oil field electrical substation\",\"authors\":\"Y. Konovalov, D. Nurbosynov\",\"doi\":\"10.1109/ICIEAM.2017.8076228\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes reactive power compensation regimes at the level of the oil field electrical substation of the oil and gas production enterprise in terms of active power losses minimization in the feed lines and transformers using local and centralized reactive power sources as well as electrotechnical complexes equipped with synchronous motors. The studies are carried out for a typical oil field electrical substation to determine the most economical mode of the reactive power compensation regime. The following values are determined during the calculations: voltages in the given points of the circuit, voltage drops in the branches of the circuit, currents in the branches, active and reactive power losses in the branches of the circuit and total power losses. Analysis of the obtained results has demonstrated that the optimal regime for the generalized circuit at the oil field electrical substation, in terms of energy saving in feed lines and power transformers, is the overcompensation regime by 30…40 % on the 6.3 kV side. This regime can be achieved by means of the reservoir pressure maintenance system synchronous motors transition to the regime of the reactive power generation. The results of the oil and gas production enterprise certification show that the majority of them have the available reactive power of the synchronous motors which makes it possible to ensure the given regime on the buses of the oil field electrical substation.\",\"PeriodicalId\":428982,\"journal\":{\"name\":\"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEAM.2017.8076228\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEAM.2017.8076228","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文介绍了油气生产企业油田变电站在采用局部和集中式无功电源以及配备同步电机的电工联合体的馈线和变压器有功损耗最小化方面的无功补偿制度。以典型油田变电站为研究对象,确定了最经济的无功补偿模式。在计算过程中确定以下值:电路给定点的电压,电路支路的电压降,支路的电流,电路支路的有功和无功损耗以及总功率损耗。对所得结果的分析表明,从馈线和电力变压器节能的角度来看,油田变电站通用电路的最佳方案是在6.3 kV侧进行30 ~ 40%的过补偿。这一状态可以通过水库压力维持系统实现同步电机向无功发电状态的过渡。油气生产企业的认证结果表明,大多数企业具有同步电机的可用无功功率,可以保证油田变电站母线的给定工况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimization of power supply system reactive power compensation at the oil field electrical substation
This paper describes reactive power compensation regimes at the level of the oil field electrical substation of the oil and gas production enterprise in terms of active power losses minimization in the feed lines and transformers using local and centralized reactive power sources as well as electrotechnical complexes equipped with synchronous motors. The studies are carried out for a typical oil field electrical substation to determine the most economical mode of the reactive power compensation regime. The following values are determined during the calculations: voltages in the given points of the circuit, voltage drops in the branches of the circuit, currents in the branches, active and reactive power losses in the branches of the circuit and total power losses. Analysis of the obtained results has demonstrated that the optimal regime for the generalized circuit at the oil field electrical substation, in terms of energy saving in feed lines and power transformers, is the overcompensation regime by 30…40 % on the 6.3 kV side. This regime can be achieved by means of the reservoir pressure maintenance system synchronous motors transition to the regime of the reactive power generation. The results of the oil and gas production enterprise certification show that the majority of them have the available reactive power of the synchronous motors which makes it possible to ensure the given regime on the buses of the oil field electrical substation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信