{"title":"从现场数据发现大型PLC计量部署中的路由异常","authors":"Francesco Marcuzzi, A. Tonello, N. A. Letizia","doi":"10.1109/ISPLC48789.2020.9115397","DOIUrl":null,"url":null,"abstract":"Advanced Metering Infrastructures (AMI) are at the base of the Smart Grid concept, as they enable, through a large deployment of metering devices, a distributed, not only energy consumption metering but also a pervasive approach to network monitoring and control. In this work we present and analyze field measurement data provided by a power network manager in order to identify routing anomalies in PLC networks that implement the G3-PLC LOADng routing protocol. In the beginning, we show different types of representations developed in order to easily visualize the network's topology and we give guidelines regarding the semantics for data structures used to describe PLC networks and their topology. We then move onto using the visual tool to incorporate routing data, to facilitate the recognition of patterns and recurring relations; considering also how the topology related to the infrastructure, we observe anomalies in the ways the protocol builds routes from nodes to the Data Concentrator. We eventually discuss how routing and geometrical properties of the topology might be related to each other.","PeriodicalId":403692,"journal":{"name":"2020 IEEE International Symposium on Power Line Communications and its Applications (ISPLC)","volume":"207 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Discovering Routing Anomalies in Large PLC Metering Deployments from Field Data\",\"authors\":\"Francesco Marcuzzi, A. Tonello, N. A. Letizia\",\"doi\":\"10.1109/ISPLC48789.2020.9115397\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Advanced Metering Infrastructures (AMI) are at the base of the Smart Grid concept, as they enable, through a large deployment of metering devices, a distributed, not only energy consumption metering but also a pervasive approach to network monitoring and control. In this work we present and analyze field measurement data provided by a power network manager in order to identify routing anomalies in PLC networks that implement the G3-PLC LOADng routing protocol. In the beginning, we show different types of representations developed in order to easily visualize the network's topology and we give guidelines regarding the semantics for data structures used to describe PLC networks and their topology. We then move onto using the visual tool to incorporate routing data, to facilitate the recognition of patterns and recurring relations; considering also how the topology related to the infrastructure, we observe anomalies in the ways the protocol builds routes from nodes to the Data Concentrator. We eventually discuss how routing and geometrical properties of the topology might be related to each other.\",\"PeriodicalId\":403692,\"journal\":{\"name\":\"2020 IEEE International Symposium on Power Line Communications and its Applications (ISPLC)\",\"volume\":\"207 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Symposium on Power Line Communications and its Applications (ISPLC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISPLC48789.2020.9115397\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Symposium on Power Line Communications and its Applications (ISPLC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPLC48789.2020.9115397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Discovering Routing Anomalies in Large PLC Metering Deployments from Field Data
Advanced Metering Infrastructures (AMI) are at the base of the Smart Grid concept, as they enable, through a large deployment of metering devices, a distributed, not only energy consumption metering but also a pervasive approach to network monitoring and control. In this work we present and analyze field measurement data provided by a power network manager in order to identify routing anomalies in PLC networks that implement the G3-PLC LOADng routing protocol. In the beginning, we show different types of representations developed in order to easily visualize the network's topology and we give guidelines regarding the semantics for data structures used to describe PLC networks and their topology. We then move onto using the visual tool to incorporate routing data, to facilitate the recognition of patterns and recurring relations; considering also how the topology related to the infrastructure, we observe anomalies in the ways the protocol builds routes from nodes to the Data Concentrator. We eventually discuss how routing and geometrical properties of the topology might be related to each other.