模糊控制有源滤波器的最佳占空比设计

A. Dell'Aquila, A. Lecci, Marco Liserre, P. Zanchetta
{"title":"模糊控制有源滤波器的最佳占空比设计","authors":"A. Dell'Aquila, A. Lecci, Marco Liserre, P. Zanchetta","doi":"10.1109/ISIE.2000.930490","DOIUrl":null,"url":null,"abstract":"The paper presents a CC-PWM shunt active filter. A fuzzy control acts on the inverter devices duty cycles ensuring an optimum current tracking. A new controller design procedure has been adopted: with a mathematical analysis a rough outline of the fuzzy rules has been possible, then they have been modified during the simulation campaign to compensate the neglected phenomena. Moreover a compensating factor has been introduced to include the mains voltage effect on the current control. In short the analysis developed and the consequent control includes all the phenomena using no knowledge of load, coupling filter or grid parameters thanks to fuzzy logic computing. The results show a very high reduction of the line current harmonic distortion with medium switching frequency.","PeriodicalId":298625,"journal":{"name":"ISIE'2000. Proceedings of the 2000 IEEE International Symposium on Industrial Electronics (Cat. No.00TH8543)","volume":"385 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Design of the optimum duty cycle for a fuzzy controlled active filter\",\"authors\":\"A. Dell'Aquila, A. Lecci, Marco Liserre, P. Zanchetta\",\"doi\":\"10.1109/ISIE.2000.930490\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents a CC-PWM shunt active filter. A fuzzy control acts on the inverter devices duty cycles ensuring an optimum current tracking. A new controller design procedure has been adopted: with a mathematical analysis a rough outline of the fuzzy rules has been possible, then they have been modified during the simulation campaign to compensate the neglected phenomena. Moreover a compensating factor has been introduced to include the mains voltage effect on the current control. In short the analysis developed and the consequent control includes all the phenomena using no knowledge of load, coupling filter or grid parameters thanks to fuzzy logic computing. The results show a very high reduction of the line current harmonic distortion with medium switching frequency.\",\"PeriodicalId\":298625,\"journal\":{\"name\":\"ISIE'2000. Proceedings of the 2000 IEEE International Symposium on Industrial Electronics (Cat. No.00TH8543)\",\"volume\":\"385 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISIE'2000. Proceedings of the 2000 IEEE International Symposium on Industrial Electronics (Cat. No.00TH8543)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2000.930490\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISIE'2000. Proceedings of the 2000 IEEE International Symposium on Industrial Electronics (Cat. No.00TH8543)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2000.930490","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文提出了一种CC-PWM并联有源滤波器。模糊控制作用于逆变器设备的占空比,确保最佳的电流跟踪。采用了一种新的控制器设计方法:通过数学分析得到模糊规则的大致轮廓,然后在仿真过程中对其进行修改以补偿被忽略的现象。此外,还引入了补偿因子,以包括市电电压对电流控制的影响。简而言之,由于模糊逻辑计算,在不知道负载、耦合滤波器或网格参数的情况下,进行了分析和随后的控制,包括所有现象。结果表明,在中等开关频率下,对线路电流谐波失真有很高的抑制作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of the optimum duty cycle for a fuzzy controlled active filter
The paper presents a CC-PWM shunt active filter. A fuzzy control acts on the inverter devices duty cycles ensuring an optimum current tracking. A new controller design procedure has been adopted: with a mathematical analysis a rough outline of the fuzzy rules has been possible, then they have been modified during the simulation campaign to compensate the neglected phenomena. Moreover a compensating factor has been introduced to include the mains voltage effect on the current control. In short the analysis developed and the consequent control includes all the phenomena using no knowledge of load, coupling filter or grid parameters thanks to fuzzy logic computing. The results show a very high reduction of the line current harmonic distortion with medium switching frequency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信