{"title":"基于自动化系统的配电网单相接地故障选线方法辅助策略研究","authors":"Zhang Beibei, Z. Jiaqi, Wang Yuanyuan, Huang Sujuan, Zhang Yulin, Xu Xi","doi":"10.1109/CICED50259.2021.9556673","DOIUrl":null,"url":null,"abstract":"In order to effectively improve the working efficiency of dispatchers using the ‘pull test method’ for single-phase ground fault line selection, this paper presents avariety of steady-state electrical quantities such as voltage, current, and reactive power obtained based on the distribution automation system, and combined with the line topology to generate fault line selection auxiliary strategies for different grounding systems that based on the superposition of multi-dimensional elements. Explained the technical principle of identifying the nature and phase of ground faults. Analyzed and introduced the organic fusion technology of fault features in multiple dimensions such as zero-sequence current amplitude, zero-sequence current mutation, reactive power mutation, etc. for different grounding methods and arc suppression coil compensation modes. Than formed \"pull test\"sequence of all lines. The proposed method does not require the addition of special hardware equipment or the transformation of the neutral point of the substation, not only saves investment, but also effectively reduces the number of line test pulls, and realizes rapid identification and accurate line selection of single-phase ground faults. The feasibility and applicability of this method were demonstrated in combination with specific projects.","PeriodicalId":221387,"journal":{"name":"2021 China International Conference on Electricity Distribution (CICED)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on Assisted Strategy of Fault Line Selecting Method for Single-phase Ground Fault in Distribution Netword Base on Automation System\",\"authors\":\"Zhang Beibei, Z. Jiaqi, Wang Yuanyuan, Huang Sujuan, Zhang Yulin, Xu Xi\",\"doi\":\"10.1109/CICED50259.2021.9556673\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to effectively improve the working efficiency of dispatchers using the ‘pull test method’ for single-phase ground fault line selection, this paper presents avariety of steady-state electrical quantities such as voltage, current, and reactive power obtained based on the distribution automation system, and combined with the line topology to generate fault line selection auxiliary strategies for different grounding systems that based on the superposition of multi-dimensional elements. Explained the technical principle of identifying the nature and phase of ground faults. Analyzed and introduced the organic fusion technology of fault features in multiple dimensions such as zero-sequence current amplitude, zero-sequence current mutation, reactive power mutation, etc. for different grounding methods and arc suppression coil compensation modes. Than formed \\\"pull test\\\"sequence of all lines. The proposed method does not require the addition of special hardware equipment or the transformation of the neutral point of the substation, not only saves investment, but also effectively reduces the number of line test pulls, and realizes rapid identification and accurate line selection of single-phase ground faults. The feasibility and applicability of this method were demonstrated in combination with specific projects.\",\"PeriodicalId\":221387,\"journal\":{\"name\":\"2021 China International Conference on Electricity Distribution (CICED)\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 China International Conference on Electricity Distribution (CICED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CICED50259.2021.9556673\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 China International Conference on Electricity Distribution (CICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CICED50259.2021.9556673","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了有效提高调度员使用“拉试验法”进行单相接地选线的工作效率,本文给出了基于配电自动化系统获得的各种电压、电流、无功等稳态电量,并结合线路拓扑,生成了基于多维要素叠加的不同接地系统的选线辅助策略。阐述了识别接地故障性质和相位的技术原理。分析并介绍了不同接地方式和消弧线圈补偿方式下零序电流幅值、零序电流突变、无功突变等多维故障特征的有机融合技术。然后形成所有线路的“拉试”顺序。所提出的方法不需要增设专用硬件设备,也不需要对变电站中性点进行改造,不仅节省了投资,而且有效地减少了线路试拔次数,实现了单相接地故障的快速识别和准确选线。结合具体工程,论证了该方法的可行性和适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on Assisted Strategy of Fault Line Selecting Method for Single-phase Ground Fault in Distribution Netword Base on Automation System
In order to effectively improve the working efficiency of dispatchers using the ‘pull test method’ for single-phase ground fault line selection, this paper presents avariety of steady-state electrical quantities such as voltage, current, and reactive power obtained based on the distribution automation system, and combined with the line topology to generate fault line selection auxiliary strategies for different grounding systems that based on the superposition of multi-dimensional elements. Explained the technical principle of identifying the nature and phase of ground faults. Analyzed and introduced the organic fusion technology of fault features in multiple dimensions such as zero-sequence current amplitude, zero-sequence current mutation, reactive power mutation, etc. for different grounding methods and arc suppression coil compensation modes. Than formed "pull test"sequence of all lines. The proposed method does not require the addition of special hardware equipment or the transformation of the neutral point of the substation, not only saves investment, but also effectively reduces the number of line test pulls, and realizes rapid identification and accurate line selection of single-phase ground faults. The feasibility and applicability of this method were demonstrated in combination with specific projects.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信