R. Dashti, J. Sadeh
{"title":"为提高可靠性和故障区段估计而进行的配电网故障指示器分配","authors":"R. Dashti, J. Sadeh","doi":"10.1109/APAP.2011.6180595","DOIUrl":null,"url":null,"abstract":"Fault indicator (FI) is used in impedance-based methods for improving fault section estimation in power distribution feeders. The location and number of FIs affects on the reliability indices and can extra charge the distribution companies and consumers. In this paper, the optimal location and number of fault indicator (FI) are determined in Power Distribution Network (PDN) with special economical combined objective function. In this objective function, four imposed costs on distribution companies and consumers are taken into account. For solving this problem, a powerful method i.e. Genetic Algorithm ( GA) is used. Then the proposed method is tested on the two case studies, which one of them is a real distribution feeder of Bushehr power distribution company in Iran. At the end the results are presented discussed.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"Fault indicator allocation in power distribution network for improving reliability and fault section estimation\",\"authors\":\"R. Dashti, J. Sadeh\",\"doi\":\"10.1109/APAP.2011.6180595\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Fault indicator (FI) is used in impedance-based methods for improving fault section estimation in power distribution feeders. The location and number of FIs affects on the reliability indices and can extra charge the distribution companies and consumers. In this paper, the optimal location and number of fault indicator (FI) are determined in Power Distribution Network (PDN) with special economical combined objective function. In this objective function, four imposed costs on distribution companies and consumers are taken into account. For solving this problem, a powerful method i.e. Genetic Algorithm ( GA) is used. Then the proposed method is tested on the two case studies, which one of them is a real distribution feeder of Bushehr power distribution company in Iran. At the end the results are presented discussed.\",\"PeriodicalId\":435652,\"journal\":{\"name\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"volume\":\"114 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APAP.2011.6180595\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180595","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

将故障指示器(FI)应用于基于阻抗的配电馈线故障区段估计方法中。fi的位置和数量会影响可靠性指标,并会给配电公司和消费者带来额外的费用。本文采用特殊的经济组合目标函数,确定了配电网中故障指示器的最优位置和数量。在这个目标函数中,考虑了分销公司和消费者的四种强加成本。为了解决这一问题,采用了一种强大的方法——遗传算法。最后,以伊朗布什尔配电公司的实际配电馈线为例,对所提出的方法进行了验证。最后对研究结果进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault indicator allocation in power distribution network for improving reliability and fault section estimation
Fault indicator (FI) is used in impedance-based methods for improving fault section estimation in power distribution feeders. The location and number of FIs affects on the reliability indices and can extra charge the distribution companies and consumers. In this paper, the optimal location and number of fault indicator (FI) are determined in Power Distribution Network (PDN) with special economical combined objective function. In this objective function, four imposed costs on distribution companies and consumers are taken into account. For solving this problem, a powerful method i.e. Genetic Algorithm ( GA) is used. Then the proposed method is tested on the two case studies, which one of them is a real distribution feeder of Bushehr power distribution company in Iran. At the end the results are presented discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信