{"title":"abc坐标系下三相D-STATCOM数字电流控制策略","authors":"T. Busarello, K. Zeb, M. Sarwar, Hee-Je Kim","doi":"10.1109/iCoMET48670.2020.9073883","DOIUrl":null,"url":null,"abstract":"This paper proposes a Three-phase D-STATCOM with digital current control strategy in abc- reference frame. The proposal D-STATCOM does not use a PLL and the reactive power is transferred to the grid through controlling the D-STATCOM output current. The current controller has one zero and two poles. This type of controller is also known as Type-2 controller. The procedure to tune the controller is explained. The Conservative Power Theory (CPT) is used to compute the reactive power of the loads. A case study shows the behavior of the D-STACOM during initialization, during load transitions and during steady-state conditions. The results show the efficacy of the proposed D-STATCOM.","PeriodicalId":431051,"journal":{"name":"2020 3rd International Conference on Computing, Mathematics and Engineering Technologies (iCoMET)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Three-Phase D-STATCOM with Digital Current Control Strategy in abc-Reference Frame\",\"authors\":\"T. Busarello, K. Zeb, M. Sarwar, Hee-Je Kim\",\"doi\":\"10.1109/iCoMET48670.2020.9073883\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a Three-phase D-STATCOM with digital current control strategy in abc- reference frame. The proposal D-STATCOM does not use a PLL and the reactive power is transferred to the grid through controlling the D-STATCOM output current. The current controller has one zero and two poles. This type of controller is also known as Type-2 controller. The procedure to tune the controller is explained. The Conservative Power Theory (CPT) is used to compute the reactive power of the loads. A case study shows the behavior of the D-STACOM during initialization, during load transitions and during steady-state conditions. The results show the efficacy of the proposed D-STATCOM.\",\"PeriodicalId\":431051,\"journal\":{\"name\":\"2020 3rd International Conference on Computing, Mathematics and Engineering Technologies (iCoMET)\",\"volume\":\"77 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Conference on Computing, Mathematics and Engineering Technologies (iCoMET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/iCoMET48670.2020.9073883\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Computing, Mathematics and Engineering Technologies (iCoMET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iCoMET48670.2020.9073883","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Three-Phase D-STATCOM with Digital Current Control Strategy in abc-Reference Frame
This paper proposes a Three-phase D-STATCOM with digital current control strategy in abc- reference frame. The proposal D-STATCOM does not use a PLL and the reactive power is transferred to the grid through controlling the D-STATCOM output current. The current controller has one zero and two poles. This type of controller is also known as Type-2 controller. The procedure to tune the controller is explained. The Conservative Power Theory (CPT) is used to compute the reactive power of the loads. A case study shows the behavior of the D-STACOM during initialization, during load transitions and during steady-state conditions. The results show the efficacy of the proposed D-STATCOM.