[咬肌肌电活动分布的定量地形特征:频谱肌电参数的映射]。

H C Scholle, N P Schumann, C Anders, E Mey
{"title":"[咬肌肌电活动分布的定量地形特征:频谱肌电参数的映射]。","authors":"H C Scholle,&nbsp;N P Schumann,&nbsp;C Anders,&nbsp;E Mey","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A new method for quantitative characterization of myoelectrical masseter activity distribution by mapping of spectral EMG-parameters is described. The surface electromyograms of M. masseter were monopolarly recorded (16 channels). On the basis of registered EMG intervals (512 ms) the spectral EMG power of several frequency bands was calculated (Fast Fourier Transformation). The spectral EMG parameters between the 16 electrode positions were estimated by linear interpolation (4-nearest neighbours algorithm). Afterwards the spectral EMG parameters were fitted in a grey-tone or colour scale with 10 intervals. The so obtained EMG activity maps (\"EMG-Maps\") permit a quantitative-topographic characterization of myoelectrical masseter activity during different functional load procedures. The frequency range which is to consider in masseter surface-EMG investigations encloses frequencies between 15 and 500 Hz. The topography of EMG activation pattern of M. masseter is only described in a comprehensive manner when the electrode array consists of 16 electrodes and more. During defined motor tasks like clenching with controlled forces the reproducibility of EMG-Maps which respect to the topography of EMG activity pattern is very high. The absolute values of spectral EMG power as well as power changes of selected band ranges during clenching correlate to the extent of chewing forces.</p>","PeriodicalId":75812,"journal":{"name":"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete","volume":"23 3","pages":"115-20"},"PeriodicalIF":0.0000,"publicationDate":"1992-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Quantitative topographic characterization of the myoelectric activity distribution of the masseter muscle: mapping of spectral EMG parameters].\",\"authors\":\"H C Scholle,&nbsp;N P Schumann,&nbsp;C Anders,&nbsp;E Mey\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A new method for quantitative characterization of myoelectrical masseter activity distribution by mapping of spectral EMG-parameters is described. The surface electromyograms of M. masseter were monopolarly recorded (16 channels). On the basis of registered EMG intervals (512 ms) the spectral EMG power of several frequency bands was calculated (Fast Fourier Transformation). The spectral EMG parameters between the 16 electrode positions were estimated by linear interpolation (4-nearest neighbours algorithm). Afterwards the spectral EMG parameters were fitted in a grey-tone or colour scale with 10 intervals. The so obtained EMG activity maps (\\\"EMG-Maps\\\") permit a quantitative-topographic characterization of myoelectrical masseter activity during different functional load procedures. The frequency range which is to consider in masseter surface-EMG investigations encloses frequencies between 15 and 500 Hz. The topography of EMG activation pattern of M. masseter is only described in a comprehensive manner when the electrode array consists of 16 electrodes and more. During defined motor tasks like clenching with controlled forces the reproducibility of EMG-Maps which respect to the topography of EMG activity pattern is very high. The absolute values of spectral EMG power as well as power changes of selected band ranges during clenching correlate to the extent of chewing forces.</p>\",\"PeriodicalId\":75812,\"journal\":{\"name\":\"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete\",\"volume\":\"23 3\",\"pages\":\"115-20\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

描述了一种利用肌电谱参数映射定量表征肌电咬肌活动分布的新方法。纵咬鼠表面肌电图呈单态记录(16通道)。在登记的肌电信号间隔(512 ms)的基础上,通过快速傅立叶变换计算出各频段的肌电信号频谱功率。通过线性插值(4近邻算法)估计16个电极位置之间的频谱肌电参数。然后将频谱肌电参数拟合为灰调或10个间隔的色阶。所获得的肌电活动图(“肌电图”)允许在不同的功能负荷过程中对肌电咬肌活动进行定量的地形表征。在咬肌表面肌电图调查中要考虑的频率范围包括15到500赫兹之间的频率。只有当电极阵列包含16个及以上电极时,才能全面描述咬肌肌电激活模式的形貌。在确定的运动任务中,如握紧控制力,与肌电活动模式地形相关的肌电图的再现性非常高。频谱肌电功率绝对值和各波段功率变化与咀嚼力的大小有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Quantitative topographic characterization of the myoelectric activity distribution of the masseter muscle: mapping of spectral EMG parameters].

A new method for quantitative characterization of myoelectrical masseter activity distribution by mapping of spectral EMG-parameters is described. The surface electromyograms of M. masseter were monopolarly recorded (16 channels). On the basis of registered EMG intervals (512 ms) the spectral EMG power of several frequency bands was calculated (Fast Fourier Transformation). The spectral EMG parameters between the 16 electrode positions were estimated by linear interpolation (4-nearest neighbours algorithm). Afterwards the spectral EMG parameters were fitted in a grey-tone or colour scale with 10 intervals. The so obtained EMG activity maps ("EMG-Maps") permit a quantitative-topographic characterization of myoelectrical masseter activity during different functional load procedures. The frequency range which is to consider in masseter surface-EMG investigations encloses frequencies between 15 and 500 Hz. The topography of EMG activation pattern of M. masseter is only described in a comprehensive manner when the electrode array consists of 16 electrodes and more. During defined motor tasks like clenching with controlled forces the reproducibility of EMG-Maps which respect to the topography of EMG activity pattern is very high. The absolute values of spectral EMG power as well as power changes of selected band ranges during clenching correlate to the extent of chewing forces.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信