两种旋转式镍钛仪器切削能力评价

R. C. Araújo, Elvira Maria Borges Gonçalves, Danilo Barral de Araújo, J. Medeiros, Maria Thereza Barral Araújo, Silvio José Albergaria da Silva
{"title":"两种旋转式镍钛仪器切削能力评价","authors":"R. C. Araújo, Elvira Maria Borges Gonçalves, Danilo Barral de Araújo, J. Medeiros, Maria Thereza Barral Araújo, Silvio José Albergaria da Silva","doi":"10.4034/pboci.2015.151.48","DOIUrl":null,"url":null,"abstract":"Objective: To perform laboratory analysis of the cutting ability of K3 and RT Densell files. Material and Methods: Fifty simulated root canals made of heat-curing phenolic resin, were divided into two groups were used. Group RT Densell consisted of specimens instrumented with files from the RT Densell rotary system, while the specimens in Group F3 were instrumented with files from the K3 rotary system. The simulated canals were weighed before and after instrumentation to analyze the amount of resin removed by each system. The statistical analysis of the results was performed using the program BioEstat 3.0. Descriptive statistics were applied to show the minimum and maximum data values, arithmetic mean, standard deviation and coefficient of variation, followed by statistical inference with a significance level of 5% Results: The data collected revealed that the rotary system nickel-titanium files of RT Densell brand removed 615 milligrams and the rotary system files K3 454 milligrams removed after five instrumentations. Through statistical test \"t\" Student, the difference between the two systems was considered statistically significant (p<0.05). Conclusion: RT Densell files have greater cutting ability than the files of the K3 brand rotary system, while the latter have.","PeriodicalId":134552,"journal":{"name":"Brazilian Research in Pediatric Dentistry and Integrated Clinic","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evaluation of Cutting Capacity in Two Types of Rotary Nickel-Titanium Instruments\",\"authors\":\"R. C. Araújo, Elvira Maria Borges Gonçalves, Danilo Barral de Araújo, J. Medeiros, Maria Thereza Barral Araújo, Silvio José Albergaria da Silva\",\"doi\":\"10.4034/pboci.2015.151.48\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: To perform laboratory analysis of the cutting ability of K3 and RT Densell files. Material and Methods: Fifty simulated root canals made of heat-curing phenolic resin, were divided into two groups were used. Group RT Densell consisted of specimens instrumented with files from the RT Densell rotary system, while the specimens in Group F3 were instrumented with files from the K3 rotary system. The simulated canals were weighed before and after instrumentation to analyze the amount of resin removed by each system. The statistical analysis of the results was performed using the program BioEstat 3.0. Descriptive statistics were applied to show the minimum and maximum data values, arithmetic mean, standard deviation and coefficient of variation, followed by statistical inference with a significance level of 5% Results: The data collected revealed that the rotary system nickel-titanium files of RT Densell brand removed 615 milligrams and the rotary system files K3 454 milligrams removed after five instrumentations. Through statistical test \\\"t\\\" Student, the difference between the two systems was considered statistically significant (p<0.05). Conclusion: RT Densell files have greater cutting ability than the files of the K3 brand rotary system, while the latter have.\",\"PeriodicalId\":134552,\"journal\":{\"name\":\"Brazilian Research in Pediatric Dentistry and Integrated Clinic\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brazilian Research in Pediatric Dentistry and Integrated Clinic\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4034/pboci.2015.151.48\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Research in Pediatric Dentistry and Integrated Clinic","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4034/pboci.2015.151.48","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的:对K3和RT Densell锉的切削能力进行实验室分析。材料与方法:采用热固化酚醛树脂制作的模拟根管50根,分为两组。RT Densell组采用RT Densell旋转系统的锉,F3组采用K3旋转系统的锉。在仪器测量前后对模拟管进行称重,以分析每种系统去除的树脂量。使用BioEstat 3.0软件对结果进行统计分析。采用描述性统计方法给出最小、最大数据值、均值、标准差和变异系数,并进行显著性水平为5%的统计推断。结果:收集到的数据显示,RT Densell品牌旋转系统镍钛锉经过5次仪器检测,去除615毫克,K3旋转系统锉去除454毫克。经统计学检验“t”Student,认为两系统差异有统计学意义(p<0.05)。结论:RT Densell锉的切削能力优于K3牌旋转系统锉,K3牌旋转系统锉的切削能力优于K3牌旋转系统锉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Cutting Capacity in Two Types of Rotary Nickel-Titanium Instruments
Objective: To perform laboratory analysis of the cutting ability of K3 and RT Densell files. Material and Methods: Fifty simulated root canals made of heat-curing phenolic resin, were divided into two groups were used. Group RT Densell consisted of specimens instrumented with files from the RT Densell rotary system, while the specimens in Group F3 were instrumented with files from the K3 rotary system. The simulated canals were weighed before and after instrumentation to analyze the amount of resin removed by each system. The statistical analysis of the results was performed using the program BioEstat 3.0. Descriptive statistics were applied to show the minimum and maximum data values, arithmetic mean, standard deviation and coefficient of variation, followed by statistical inference with a significance level of 5% Results: The data collected revealed that the rotary system nickel-titanium files of RT Densell brand removed 615 milligrams and the rotary system files K3 454 milligrams removed after five instrumentations. Through statistical test "t" Student, the difference between the two systems was considered statistically significant (p<0.05). Conclusion: RT Densell files have greater cutting ability than the files of the K3 brand rotary system, while the latter have.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信