基于电流/电压扰动的直流分布式电力系统稳定裕度监测

Jinjun Liu, Xiaogang Feng, F. Lee, D. Borojevich
{"title":"基于电流/电压扰动的直流分布式电力系统稳定裕度监测","authors":"Jinjun Liu, Xiaogang Feng, F. Lee, D. Borojevich","doi":"10.1109/APEC.2001.912453","DOIUrl":null,"url":null,"abstract":"The small-signal stability issues in multi-module power electronics systems, especially DC distributed power systems, are often dealt with by employing the impedance criterion. However, for online system stability monitoring, directly measuring impedance of the source and load subsystems then making comparisons is too complicated and difficult. This paper proposes practical and simple methods, which involve applying current or voltage perturbation to the DC side of distributed power systems then only measuring the amplitude of two currents or voltages in order to monitor the stability margin. For both methods (current perturbation and voltage perturbation), an implementation approach that does not employ external voltage perturbation source is also presented. A comparative evaluation of each method and its corresponding implementation approach is provided.","PeriodicalId":201844,"journal":{"name":"APEC 2001. Sixteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.01CH37181)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":"{\"title\":\"Stability margin monitoring for DC distributed power systems via current/voltage perturbation\",\"authors\":\"Jinjun Liu, Xiaogang Feng, F. Lee, D. Borojevich\",\"doi\":\"10.1109/APEC.2001.912453\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The small-signal stability issues in multi-module power electronics systems, especially DC distributed power systems, are often dealt with by employing the impedance criterion. However, for online system stability monitoring, directly measuring impedance of the source and load subsystems then making comparisons is too complicated and difficult. This paper proposes practical and simple methods, which involve applying current or voltage perturbation to the DC side of distributed power systems then only measuring the amplitude of two currents or voltages in order to monitor the stability margin. For both methods (current perturbation and voltage perturbation), an implementation approach that does not employ external voltage perturbation source is also presented. A comparative evaluation of each method and its corresponding implementation approach is provided.\",\"PeriodicalId\":201844,\"journal\":{\"name\":\"APEC 2001. Sixteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.01CH37181)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"30\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"APEC 2001. Sixteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.01CH37181)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2001.912453\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"APEC 2001. Sixteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.01CH37181)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2001.912453","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

摘要

多模块电力电子系统,特别是直流分布式电力系统中的小信号稳定性问题,通常采用阻抗判据来解决。然而,对于在线系统稳定性监测,直接测量源、负载子系统的阻抗并进行比较是非常复杂和困难的。本文提出了一种实用而简单的方法,即对分布式电力系统的直流侧施加电流或电压扰动,然后仅测量两个电流或电压的幅值,以监测稳定裕度。对于电流摄动和电压摄动两种方法,本文还提出了一种不采用外部电压摄动源的实现方法。对每种方法及其相应的实现方法进行了比较评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Stability margin monitoring for DC distributed power systems via current/voltage perturbation
The small-signal stability issues in multi-module power electronics systems, especially DC distributed power systems, are often dealt with by employing the impedance criterion. However, for online system stability monitoring, directly measuring impedance of the source and load subsystems then making comparisons is too complicated and difficult. This paper proposes practical and simple methods, which involve applying current or voltage perturbation to the DC side of distributed power systems then only measuring the amplitude of two currents or voltages in order to monitor the stability margin. For both methods (current perturbation and voltage perturbation), an implementation approach that does not employ external voltage perturbation source is also presented. A comparative evaluation of each method and its corresponding implementation approach is provided.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信