QianYong Liu, Xinran Li, Xiaojuan Li, B. Lei, Desheng Chen, Yuan Pan
{"title":"牵引负荷负序电流对电网运行状态的影响","authors":"QianYong Liu, Xinran Li, Xiaojuan Li, B. Lei, Desheng Chen, Yuan Pan","doi":"10.1109/APAP.2011.6180535","DOIUrl":null,"url":null,"abstract":"On the basis of considerable amount of measured wave-recording data of electrical traction load, this paper used the measurement-based method to establish models of negative sequence current source in different traction working conditions. The establishment of UDM in PSASP has enabled the information exchange between models of negative sequence current source and the harmonic analysis and calculation in PSASP. With WEPRI-36 nodes set as network background to conduct the simulation of grade operating state, this paper systematically analyze the influence that traction load has on a series of aspects like generator, transformer, line and relay protection by making comparison between simulation results of different traction transformers. Accordingly, corresponding measures are put forward.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Impact of negative sequence current of traction load on the grid running state\",\"authors\":\"QianYong Liu, Xinran Li, Xiaojuan Li, B. Lei, Desheng Chen, Yuan Pan\",\"doi\":\"10.1109/APAP.2011.6180535\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"On the basis of considerable amount of measured wave-recording data of electrical traction load, this paper used the measurement-based method to establish models of negative sequence current source in different traction working conditions. The establishment of UDM in PSASP has enabled the information exchange between models of negative sequence current source and the harmonic analysis and calculation in PSASP. With WEPRI-36 nodes set as network background to conduct the simulation of grade operating state, this paper systematically analyze the influence that traction load has on a series of aspects like generator, transformer, line and relay protection by making comparison between simulation results of different traction transformers. Accordingly, corresponding measures are put forward.\",\"PeriodicalId\":435652,\"journal\":{\"name\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APAP.2011.6180535\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Impact of negative sequence current of traction load on the grid running state
On the basis of considerable amount of measured wave-recording data of electrical traction load, this paper used the measurement-based method to establish models of negative sequence current source in different traction working conditions. The establishment of UDM in PSASP has enabled the information exchange between models of negative sequence current source and the harmonic analysis and calculation in PSASP. With WEPRI-36 nodes set as network background to conduct the simulation of grade operating state, this paper systematically analyze the influence that traction load has on a series of aspects like generator, transformer, line and relay protection by making comparison between simulation results of different traction transformers. Accordingly, corresponding measures are put forward.