电晕放电消除电荷对高聚物接触充电特性的影响

T. Hase, I. Hiyoshi, Y. Murata
{"title":"电晕放电消除电荷对高聚物接触充电特性的影响","authors":"T. Hase, I. Hiyoshi, Y. Murata","doi":"10.1109/IAS.1995.530484","DOIUrl":null,"url":null,"abstract":"Charge elimination using ions generated by corona discharge in N/sub 2/ gas is investigated. An electrode system composed of a needle and a disc electrode was used for a charge eliminator and Ions are took out of a small aperture of the disk by gas flow. The electrostatic charge on both sides of polymer film is satisfactorily eliminated at the same time using two eliminators. When the sample film is directly exposed to corona at the point of needle during charge eliminating treatment, it is observed that, after this treatment, the contact charging characteristics of polyethylene changed seriously. When the sample surface is indirectly exposed by conveying ions to the sample using a bent pipe, this effect can be avoided.","PeriodicalId":117576,"journal":{"name":"IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of charge elimination by corona discharge on the characteristics of contact charging of high polymers\",\"authors\":\"T. Hase, I. Hiyoshi, Y. Murata\",\"doi\":\"10.1109/IAS.1995.530484\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Charge elimination using ions generated by corona discharge in N/sub 2/ gas is investigated. An electrode system composed of a needle and a disc electrode was used for a charge eliminator and Ions are took out of a small aperture of the disk by gas flow. The electrostatic charge on both sides of polymer film is satisfactorily eliminated at the same time using two eliminators. When the sample film is directly exposed to corona at the point of needle during charge eliminating treatment, it is observed that, after this treatment, the contact charging characteristics of polyethylene changed seriously. When the sample surface is indirectly exposed by conveying ions to the sample using a bent pipe, this effect can be avoided.\",\"PeriodicalId\":117576,\"journal\":{\"name\":\"IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1995.530484\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1995.530484","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了N/ sub2 /气体中电晕放电产生的离子的电荷消除。电荷消除器采用针电极和圆盘电极组成的电极系统,通过气流将离子从圆盘的小孔中取出。采用两种消除器同时消除了聚合物膜两侧的静电荷,令人满意。在消电荷处理过程中,将样品膜直接暴露在针尖处的电晕下,观察到该处理后,聚乙烯的接触充电特性发生了严重变化。当使用弯曲管向样品输送离子时,间接暴露样品表面,可以避免这种影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The effect of charge elimination by corona discharge on the characteristics of contact charging of high polymers
Charge elimination using ions generated by corona discharge in N/sub 2/ gas is investigated. An electrode system composed of a needle and a disc electrode was used for a charge eliminator and Ions are took out of a small aperture of the disk by gas flow. The electrostatic charge on both sides of polymer film is satisfactorily eliminated at the same time using two eliminators. When the sample film is directly exposed to corona at the point of needle during charge eliminating treatment, it is observed that, after this treatment, the contact charging characteristics of polyethylene changed seriously. When the sample surface is indirectly exposed by conveying ions to the sample using a bent pipe, this effect can be avoided.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信