{"title":"底线:","authors":"D. Sarrett, RelyX Luting","doi":"10.2307/j.ctv1675b9g.13","DOIUrl":null,"url":null,"abstract":"ISSN 1930-8736 Editor: David C. Sarrett, DMD, MS ppreditor@ada.org Glass Ionomer Cements Between the two self-curing pure glass ionomers evaluated, GlassLute failed to meet minimum standards for strength and acid erosion. GC Fuji Cem, GC Fuji PLUS, and RelyX Luting Plus (all resin-modified glass ionomers) were highly rated products in the survey among clinicians. GC Fuji Cem had the most favorable film thickness of all cements tested when loaded immediately; however it was completely set when tested at the manufacturer’s stated working time. GC Fuji Plus (a RMGI) and PermaCem Dual Smartmix, a compomer more comparable to a resin cement, had the highest laboratory scores. GC Fuji Plus, a resin-modified glass ionomer, appears to be a good overall choice for a luting cement with glass ionomer advantages. It had among the highest laboratory scores and ratings among clinicians.","PeriodicalId":269645,"journal":{"name":"A&R Pioneers","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Bottom Line:\",\"authors\":\"D. Sarrett, RelyX Luting\",\"doi\":\"10.2307/j.ctv1675b9g.13\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ISSN 1930-8736 Editor: David C. Sarrett, DMD, MS ppreditor@ada.org Glass Ionomer Cements Between the two self-curing pure glass ionomers evaluated, GlassLute failed to meet minimum standards for strength and acid erosion. GC Fuji Cem, GC Fuji PLUS, and RelyX Luting Plus (all resin-modified glass ionomers) were highly rated products in the survey among clinicians. GC Fuji Cem had the most favorable film thickness of all cements tested when loaded immediately; however it was completely set when tested at the manufacturer’s stated working time. GC Fuji Plus (a RMGI) and PermaCem Dual Smartmix, a compomer more comparable to a resin cement, had the highest laboratory scores. GC Fuji Plus, a resin-modified glass ionomer, appears to be a good overall choice for a luting cement with glass ionomer advantages. It had among the highest laboratory scores and ratings among clinicians.\",\"PeriodicalId\":269645,\"journal\":{\"name\":\"A&R Pioneers\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"A&R Pioneers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2307/j.ctv1675b9g.13\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"A&R Pioneers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2307/j.ctv1675b9g.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
编辑:David C. Sarrett, DMD, MS ppreditor@ada.org玻璃离聚物水泥在两种自固化纯玻璃离聚物之间进行评估,GlassLute未能达到强度和酸侵蚀的最低标准。GC Fuji Cem、GC Fuji PLUS和RelyX Luting PLUS(所有树脂改性玻璃离子)在临床医生的调查中被高度评价。GC富士铈在立即加载时的膜厚是所有水泥中最好的;然而,当在制造商规定的工作时间测试时,它是完全设置的。GC Fuji Plus (RMGI)和PermaCem Dual Smartmix(一种更接近树脂水泥的复合材料)的实验室得分最高。GC Fuji Plus是一种树脂改性的玻璃离聚体,对于具有玻璃离聚体优势的水泥来说,似乎是一个很好的整体选择。它在临床医生中拥有最高的实验室分数和评级。
ISSN 1930-8736 Editor: David C. Sarrett, DMD, MS ppreditor@ada.org Glass Ionomer Cements Between the two self-curing pure glass ionomers evaluated, GlassLute failed to meet minimum standards for strength and acid erosion. GC Fuji Cem, GC Fuji PLUS, and RelyX Luting Plus (all resin-modified glass ionomers) were highly rated products in the survey among clinicians. GC Fuji Cem had the most favorable film thickness of all cements tested when loaded immediately; however it was completely set when tested at the manufacturer’s stated working time. GC Fuji Plus (a RMGI) and PermaCem Dual Smartmix, a compomer more comparable to a resin cement, had the highest laboratory scores. GC Fuji Plus, a resin-modified glass ionomer, appears to be a good overall choice for a luting cement with glass ionomer advantages. It had among the highest laboratory scores and ratings among clinicians.