{"title":"通过附加表面层的热传导来控制最低热通量点温度:B系列:流体工程,传热,燃烧,动力,热物理性质","authors":"S. Nishio, Yoshihiro Serizawa","doi":"10.1299/KIKAIB.53.1061","DOIUrl":null,"url":null,"abstract":"In the present paper, the effects of thermal conductance of a boiling surface on the minimum-heat-flux-point temperature and film-boiling heat transfer of saturated pool boiling of liquid nitrogen on a horizontal flat-surface of copper are experimentally studied. The thermal conductance of the copper surface was changed by the following two additional-layers coated on it. The first is a thin layer of low thermal-conductivity material coated on the copper surface. The second is a additional double-layer that consists of a 0.3 mm PTFE layer and a thin metallic layer coated on it. The experimental results show that the effects of such additional layers on film boiling are negligible but are remarkable on the MHF-point temperature. For the single insulating layers, the MHF-point temperature increases with increased coating thicknesses. As for the additional double-layers, the MHF-point temperature decreses rapidly with increased thicknesses of the outer layer. In both cases, the MHF-point temperature reaches (or comes back to) a unique value when the coating material has a coating thickness of 0.1∼1 mm.","PeriodicalId":286527,"journal":{"name":"JSME international journal : bulletin of the JSME","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1987-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Control of Minimum-Heat-Flux-Point Temperature by the Thermal Conductance of an Additional Surface-Layer : Series B : Fluid Engineering, Heat Transfer, Combustion, Power, Thermophysical Properties\",\"authors\":\"S. Nishio, Yoshihiro Serizawa\",\"doi\":\"10.1299/KIKAIB.53.1061\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present paper, the effects of thermal conductance of a boiling surface on the minimum-heat-flux-point temperature and film-boiling heat transfer of saturated pool boiling of liquid nitrogen on a horizontal flat-surface of copper are experimentally studied. The thermal conductance of the copper surface was changed by the following two additional-layers coated on it. The first is a thin layer of low thermal-conductivity material coated on the copper surface. The second is a additional double-layer that consists of a 0.3 mm PTFE layer and a thin metallic layer coated on it. The experimental results show that the effects of such additional layers on film boiling are negligible but are remarkable on the MHF-point temperature. For the single insulating layers, the MHF-point temperature increases with increased coating thicknesses. As for the additional double-layers, the MHF-point temperature decreses rapidly with increased thicknesses of the outer layer. In both cases, the MHF-point temperature reaches (or comes back to) a unique value when the coating material has a coating thickness of 0.1∼1 mm.\",\"PeriodicalId\":286527,\"journal\":{\"name\":\"JSME international journal : bulletin of the JSME\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1987-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JSME international journal : bulletin of the JSME\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1299/KIKAIB.53.1061\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSME international journal : bulletin of the JSME","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1299/KIKAIB.53.1061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Control of Minimum-Heat-Flux-Point Temperature by the Thermal Conductance of an Additional Surface-Layer : Series B : Fluid Engineering, Heat Transfer, Combustion, Power, Thermophysical Properties
In the present paper, the effects of thermal conductance of a boiling surface on the minimum-heat-flux-point temperature and film-boiling heat transfer of saturated pool boiling of liquid nitrogen on a horizontal flat-surface of copper are experimentally studied. The thermal conductance of the copper surface was changed by the following two additional-layers coated on it. The first is a thin layer of low thermal-conductivity material coated on the copper surface. The second is a additional double-layer that consists of a 0.3 mm PTFE layer and a thin metallic layer coated on it. The experimental results show that the effects of such additional layers on film boiling are negligible but are remarkable on the MHF-point temperature. For the single insulating layers, the MHF-point temperature increases with increased coating thicknesses. As for the additional double-layers, the MHF-point temperature decreses rapidly with increased thicknesses of the outer layer. In both cases, the MHF-point temperature reaches (or comes back to) a unique value when the coating material has a coating thickness of 0.1∼1 mm.