选择电力系统的减载位置*

T. N. Le, H. Quyen, T. Phan, N. A. Nguyen, Tan Trieu
{"title":"选择电力系统的减载位置*","authors":"T. N. Le, H. Quyen, T. Phan, N. A. Nguyen, Tan Trieu","doi":"10.1109/GTSD.2018.8595559","DOIUrl":null,"url":null,"abstract":"When there is a large power imbalance, the frequency of the power system will be declined lower than the allowable value. Therefore, maintaining the frequency within the allowable value is essential. In the case of an emergency control such as a large generator trip, an effective load shedding plan is required to avoid frequency dropping and blackout. This paper introduces a new method for determining the location of the load shedding by using the phase angle sensitivity of two buses. Load shedding is based on the calculation sensitivity from the loads to the generator outage location. The shorter the loads have sensitivity; the larger capacity loads will shed. Experiment results showed the amount of load shedding is lower, the recovery time of frequency and rotor angle are faster than the conventional load shedding.","PeriodicalId":344653,"journal":{"name":"2018 4th International Conference on Green Technology and Sustainable Development (GTSD)","volume":"22 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Select Location for Load Shedding In Power System*\",\"authors\":\"T. N. Le, H. Quyen, T. Phan, N. A. Nguyen, Tan Trieu\",\"doi\":\"10.1109/GTSD.2018.8595559\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When there is a large power imbalance, the frequency of the power system will be declined lower than the allowable value. Therefore, maintaining the frequency within the allowable value is essential. In the case of an emergency control such as a large generator trip, an effective load shedding plan is required to avoid frequency dropping and blackout. This paper introduces a new method for determining the location of the load shedding by using the phase angle sensitivity of two buses. Load shedding is based on the calculation sensitivity from the loads to the generator outage location. The shorter the loads have sensitivity; the larger capacity loads will shed. Experiment results showed the amount of load shedding is lower, the recovery time of frequency and rotor angle are faster than the conventional load shedding.\",\"PeriodicalId\":344653,\"journal\":{\"name\":\"2018 4th International Conference on Green Technology and Sustainable Development (GTSD)\",\"volume\":\"22 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 4th International Conference on Green Technology and Sustainable Development (GTSD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GTSD.2018.8595559\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 4th International Conference on Green Technology and Sustainable Development (GTSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GTSD.2018.8595559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

当存在较大的功率不平衡时,电力系统的频率将下降到允许的值以下。因此,保持频率在允许值内是必不可少的。在大型发电机跳闸等紧急控制情况下,需要有效的减载方案来避免频率下降和停电。本文介绍了一种利用双母线相角灵敏度确定减载位置的新方法。减载是基于从负荷到发电机停运位置的计算灵敏度。负载的灵敏度越短;容量较大的负载将减少。实验结果表明,与传统的减载方式相比,该减载方式的减载量更小,频率和转子角的恢复时间更快。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Select Location for Load Shedding In Power System*
When there is a large power imbalance, the frequency of the power system will be declined lower than the allowable value. Therefore, maintaining the frequency within the allowable value is essential. In the case of an emergency control such as a large generator trip, an effective load shedding plan is required to avoid frequency dropping and blackout. This paper introduces a new method for determining the location of the load shedding by using the phase angle sensitivity of two buses. Load shedding is based on the calculation sensitivity from the loads to the generator outage location. The shorter the loads have sensitivity; the larger capacity loads will shed. Experiment results showed the amount of load shedding is lower, the recovery time of frequency and rotor angle are faster than the conventional load shedding.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信