{"title":"操作人员运动对洁净室气溶胶粒子分布的影响","authors":"V. Sharaeva, Mikhail A. Gundartcev, V. Karakeyan, Andrei S. Riabyshenkov, Darya D. Redichkina","doi":"10.1109/ElConRus51938.2021.9396432","DOIUrl":null,"url":null,"abstract":"One of the keyword parameters of the technological microclimate in microelectronics clean rooms is the laminar air flow. It is important not only the creation a flow, but also its stable nature during the performance of technological operations. The article presents the mathematical modeling results of aerosol particles behavior when the operator performs characteristic movements for different motions of the laminar air flow. Regularities have been obtained that establish situations that are least favorable for the technological process, which makes it possible to make practical correction to the regulations for the operation of clean rooms.","PeriodicalId":447345,"journal":{"name":"2021 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (ElConRus)","volume":"164 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of Operator Movement on Aerosol Particles the Distribution in Clean Rooms\",\"authors\":\"V. Sharaeva, Mikhail A. Gundartcev, V. Karakeyan, Andrei S. Riabyshenkov, Darya D. Redichkina\",\"doi\":\"10.1109/ElConRus51938.2021.9396432\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the keyword parameters of the technological microclimate in microelectronics clean rooms is the laminar air flow. It is important not only the creation a flow, but also its stable nature during the performance of technological operations. The article presents the mathematical modeling results of aerosol particles behavior when the operator performs characteristic movements for different motions of the laminar air flow. Regularities have been obtained that establish situations that are least favorable for the technological process, which makes it possible to make practical correction to the regulations for the operation of clean rooms.\",\"PeriodicalId\":447345,\"journal\":{\"name\":\"2021 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (ElConRus)\",\"volume\":\"164 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (ElConRus)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ElConRus51938.2021.9396432\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (ElConRus)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ElConRus51938.2021.9396432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Influence of Operator Movement on Aerosol Particles the Distribution in Clean Rooms
One of the keyword parameters of the technological microclimate in microelectronics clean rooms is the laminar air flow. It is important not only the creation a flow, but also its stable nature during the performance of technological operations. The article presents the mathematical modeling results of aerosol particles behavior when the operator performs characteristic movements for different motions of the laminar air flow. Regularities have been obtained that establish situations that are least favorable for the technological process, which makes it possible to make practical correction to the regulations for the operation of clean rooms.