复合材料层合板缺陷检测的平板扫描图像和单超声测距技术

M. F. Mahmod, M. Z. M. Pauzi, E. A. Bakar
{"title":"复合材料层合板缺陷检测的平板扫描图像和单超声测距技术","authors":"M. F. Mahmod, M. Z. M. Pauzi, E. A. Bakar","doi":"10.1109/ICSIMA.2013.6717929","DOIUrl":null,"url":null,"abstract":"Inspection of composite laminates in production line using Ultrasonic C-scan for NDT requires a competent and experience inspector in order to analyze the signal which involve various technical instruction. In this paper, two approaches had been used which are image based approach and signal based approach of ultrasonic C-Scan method for NDT of composite laminate are developed and applied, with the aim to compare and validate both techniques instead of surface defect percentage area. The idea is, to propose an image analysis technique which easy to handle by general worker either the defect percentage area between the image and signal analysis are acceptable range or not. Composite laminates 6 plies which produced in-house with geometry 280 mm length × 80 mm width × 2 mm thickness was drilled to consider as defect area. Then, further analysis was performed using image scanning and processing to calculate the percentage of the defect area before we proceeds to the ultrasonic signal based approach. This research had been successfully done with the maximum and the minimum yield percentage between image processing and ultrasonic signal based approach method are 17.12 percent and 8.52 percent.","PeriodicalId":182424,"journal":{"name":"2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA)","volume":"362 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Flatbed scanner image and single ultrasonic rangefinder technique for composite laminates defect detection\",\"authors\":\"M. F. Mahmod, M. Z. M. Pauzi, E. A. Bakar\",\"doi\":\"10.1109/ICSIMA.2013.6717929\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inspection of composite laminates in production line using Ultrasonic C-scan for NDT requires a competent and experience inspector in order to analyze the signal which involve various technical instruction. In this paper, two approaches had been used which are image based approach and signal based approach of ultrasonic C-Scan method for NDT of composite laminate are developed and applied, with the aim to compare and validate both techniques instead of surface defect percentage area. The idea is, to propose an image analysis technique which easy to handle by general worker either the defect percentage area between the image and signal analysis are acceptable range or not. Composite laminates 6 plies which produced in-house with geometry 280 mm length × 80 mm width × 2 mm thickness was drilled to consider as defect area. Then, further analysis was performed using image scanning and processing to calculate the percentage of the defect area before we proceeds to the ultrasonic signal based approach. This research had been successfully done with the maximum and the minimum yield percentage between image processing and ultrasonic signal based approach method are 17.12 percent and 8.52 percent.\",\"PeriodicalId\":182424,\"journal\":{\"name\":\"2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA)\",\"volume\":\"362 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSIMA.2013.6717929\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSIMA.2013.6717929","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在复合材料层压板的生产线上使用超声c扫描进行无损检测,需要一名有能力和经验的检测人员对涉及各种技术指令的信号进行分析。本文将基于图像的超声c扫描方法和基于信号的超声c扫描方法两种方法应用于复合材料层合板的无损检测中,目的是对两种方法进行比较和验证,而不是对表面缺陷面积百分比进行检测。其思想是提出一种易于操作的图像分析技术,无论图像与信号分析之间的缺陷百分比面积是否在可接受范围内。内部生产的6层复合材料层压板,几何形状为280毫米长× 80毫米宽× 2毫米厚,钻孔考虑为缺陷区域。然后,在进行基于超声信号的方法之前,使用图像扫描和处理进行进一步分析以计算缺陷面积的百分比。研究结果表明,图像处理与基于超声信号的方法的最大良率为17.12%,最小良率为8.52%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Flatbed scanner image and single ultrasonic rangefinder technique for composite laminates defect detection
Inspection of composite laminates in production line using Ultrasonic C-scan for NDT requires a competent and experience inspector in order to analyze the signal which involve various technical instruction. In this paper, two approaches had been used which are image based approach and signal based approach of ultrasonic C-Scan method for NDT of composite laminate are developed and applied, with the aim to compare and validate both techniques instead of surface defect percentage area. The idea is, to propose an image analysis technique which easy to handle by general worker either the defect percentage area between the image and signal analysis are acceptable range or not. Composite laminates 6 plies which produced in-house with geometry 280 mm length × 80 mm width × 2 mm thickness was drilled to consider as defect area. Then, further analysis was performed using image scanning and processing to calculate the percentage of the defect area before we proceeds to the ultrasonic signal based approach. This research had been successfully done with the maximum and the minimum yield percentage between image processing and ultrasonic signal based approach method are 17.12 percent and 8.52 percent.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信