{"title":"过流继电器与开发的PMU型保护的比较","authors":"A. Saran","doi":"10.1109/NAPS.2013.6666919","DOIUrl":null,"url":null,"abstract":"Power system protection is still one of the primary focus of the utility companies. Phasor Measurement Unit (PMU) is used to measure the data of the transmission line, buses and the equipment's associated with it. The data measured by the PMU's at different locations can be used to make the decisions for faulty and healthy zone in the power system. During fault condition at specific location in the power system, the data measured by PMU will show abrupt increase or decrease in the physical quantities like voltage, current, and phase angles. Based on the PMU values the relays associated with the faulty transmission lines will be triggered which in turn helps to isolate only the faulty portion of the system from the rest of the healthy portion of the power system. This paper will compare two protection schemes: one protection scheme is based solely on the protective relays while the other protection scheme utilizes both the protective relays and the PMUs. Both the protection schemes were tested in real time (using RTDS) on the 3-bus power system for all kinds of line-to-ground faults.","PeriodicalId":421943,"journal":{"name":"2013 North American Power Symposium (NAPS)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Comparison between overcurrent relay and developed PMU based protection\",\"authors\":\"A. Saran\",\"doi\":\"10.1109/NAPS.2013.6666919\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power system protection is still one of the primary focus of the utility companies. Phasor Measurement Unit (PMU) is used to measure the data of the transmission line, buses and the equipment's associated with it. The data measured by the PMU's at different locations can be used to make the decisions for faulty and healthy zone in the power system. During fault condition at specific location in the power system, the data measured by PMU will show abrupt increase or decrease in the physical quantities like voltage, current, and phase angles. Based on the PMU values the relays associated with the faulty transmission lines will be triggered which in turn helps to isolate only the faulty portion of the system from the rest of the healthy portion of the power system. This paper will compare two protection schemes: one protection scheme is based solely on the protective relays while the other protection scheme utilizes both the protective relays and the PMUs. Both the protection schemes were tested in real time (using RTDS) on the 3-bus power system for all kinds of line-to-ground faults.\",\"PeriodicalId\":421943,\"journal\":{\"name\":\"2013 North American Power Symposium (NAPS)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 North American Power Symposium (NAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2013.6666919\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2013.6666919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

电力系统保护仍然是电力公司关注的重点之一。相量测量单元(PMU)用于测量传输线、母线及其相关设备的数据。PMU在不同位置的测量数据可用于电力系统的故障区和健康区决策。在电力系统特定位置的故障状态下,PMU测量的数据会显示电压、电流、相角等物理量的突然增加或减少。根据PMU值,与故障传输线相关的继电器将被触发,这反过来有助于将系统的故障部分与电力系统的其余健康部分隔离开来。本文将比较两种保护方案:一种保护方案仅基于保护继电器,另一种保护方案同时利用保护继电器和pmu。在三母线电力系统上对两种保护方案进行了实时(RTDS)测试,以应对各种线路对地故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison between overcurrent relay and developed PMU based protection
Power system protection is still one of the primary focus of the utility companies. Phasor Measurement Unit (PMU) is used to measure the data of the transmission line, buses and the equipment's associated with it. The data measured by the PMU's at different locations can be used to make the decisions for faulty and healthy zone in the power system. During fault condition at specific location in the power system, the data measured by PMU will show abrupt increase or decrease in the physical quantities like voltage, current, and phase angles. Based on the PMU values the relays associated with the faulty transmission lines will be triggered which in turn helps to isolate only the faulty portion of the system from the rest of the healthy portion of the power system. This paper will compare two protection schemes: one protection scheme is based solely on the protective relays while the other protection scheme utilizes both the protective relays and the PMUs. Both the protection schemes were tested in real time (using RTDS) on the 3-bus power system for all kinds of line-to-ground faults.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信