{"title":"内部放电脉冲测量采用微电脑","authors":"H. Matsuzaki, T. Ito, Y. Ehara, T. Sakai, P. Mckenny, M. S. A. A. Hammarn","doi":"10.1109/CEIDP.1986.7726480","DOIUrl":null,"url":null,"abstract":"The purpose of this research was to predict breakdown of electrical equipment due to deterioration of insulation. An internal discharge pulse measurement system which could analyze the distribution of the discharge according to each phase area of the applied voltage (AC 50Hz) was developed. The system's features were as follows. A half cycle of the applied voltage starting from the negative peak and ending at the positive peak was divided into nine equal phase areas. The distribution of the discharge in each phase area was expressed with a three dimensional displaying method whose dimensions were discharge magnitude (q), number of pulses (n), and time (t).","PeriodicalId":354533,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1986","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1986-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Internal discharge pulse measurement using a microcomputer\",\"authors\":\"H. Matsuzaki, T. Ito, Y. Ehara, T. Sakai, P. Mckenny, M. S. A. A. Hammarn\",\"doi\":\"10.1109/CEIDP.1986.7726480\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this research was to predict breakdown of electrical equipment due to deterioration of insulation. An internal discharge pulse measurement system which could analyze the distribution of the discharge according to each phase area of the applied voltage (AC 50Hz) was developed. The system's features were as follows. A half cycle of the applied voltage starting from the negative peak and ending at the positive peak was divided into nine equal phase areas. The distribution of the discharge in each phase area was expressed with a three dimensional displaying method whose dimensions were discharge magnitude (q), number of pulses (n), and time (t).\",\"PeriodicalId\":354533,\"journal\":{\"name\":\"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1986\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1986\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1986.7726480\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1986","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1986.7726480","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

这项研究的目的是预测由于绝缘恶化而导致的电气设备故障。研制了一种内部放电脉冲测量系统,该系统可以根据外加电压(交流50Hz)的各相区分析放电分布。该系统的特点如下:从负峰开始到正峰结束的半个周期的外加电压被划分为九个相等的相区。用三维显示的方法表示各相区的放电分布,三维显示的维度分别为放电幅度q、脉冲数n和时间t。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Internal discharge pulse measurement using a microcomputer
The purpose of this research was to predict breakdown of electrical equipment due to deterioration of insulation. An internal discharge pulse measurement system which could analyze the distribution of the discharge according to each phase area of the applied voltage (AC 50Hz) was developed. The system's features were as follows. A half cycle of the applied voltage starting from the negative peak and ending at the positive peak was divided into nine equal phase areas. The distribution of the discharge in each phase area was expressed with a three dimensional displaying method whose dimensions were discharge magnitude (q), number of pulses (n), and time (t).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信