{"title":"基于非计划互通的两区电力市场二次控制优化","authors":"S. Pujara, C. Kotwal","doi":"10.1109/NUICONE.2015.7449625","DOIUrl":null,"url":null,"abstract":"This paper describes the design and simulation of Unscheduled Interchange (UI) based optimized integral controller of Automatic Generation Control (AGC) in the restructured power system. The traditional AGC loop is replaced with UI based price signal linking to the frequency at the prevailing time. UI rate for corresponding system frequency signal is received from load dispatch center and it is compared with the marginal cost of individual generators to generate the error signal which decides the gain of integral controller for correction in frequency to its nominal value. The simulation is carried out for different cases of generation-demand transactions for two area restructured electricity market to demonstrate the effectiveness of UI based control in system frequency regulations. A non derivative classical Particle Swarm Optimization (PSO) technique is used to obtain the optimal value of gain of integral controllers to achieve the optimum response of the system under study.","PeriodicalId":131332,"journal":{"name":"2015 5th Nirma University International Conference on Engineering (NUiCONE)","volume":"22 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimized unscheduled interchange based secondary control for two area deregulated electricity market\",\"authors\":\"S. Pujara, C. Kotwal\",\"doi\":\"10.1109/NUICONE.2015.7449625\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the design and simulation of Unscheduled Interchange (UI) based optimized integral controller of Automatic Generation Control (AGC) in the restructured power system. The traditional AGC loop is replaced with UI based price signal linking to the frequency at the prevailing time. UI rate for corresponding system frequency signal is received from load dispatch center and it is compared with the marginal cost of individual generators to generate the error signal which decides the gain of integral controller for correction in frequency to its nominal value. The simulation is carried out for different cases of generation-demand transactions for two area restructured electricity market to demonstrate the effectiveness of UI based control in system frequency regulations. A non derivative classical Particle Swarm Optimization (PSO) technique is used to obtain the optimal value of gain of integral controllers to achieve the optimum response of the system under study.\",\"PeriodicalId\":131332,\"journal\":{\"name\":\"2015 5th Nirma University International Conference on Engineering (NUiCONE)\",\"volume\":\"22 5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 5th Nirma University International Conference on Engineering (NUiCONE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NUICONE.2015.7449625\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 5th Nirma University International Conference on Engineering (NUiCONE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NUICONE.2015.7449625","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了重构电力系统中基于非计划交换(UI)的自动发电控制(AGC)优化控制器的设计与仿真。传统的AGC回路被基于UI的价格信号取代,该信号与现行时间的频率相关联。从负荷调度中心接收相应系统频率信号的UI率,并将其与各发电机产生误差信号的边际成本进行比较,从而决定积分控制器将频率修正到标称值的增益。通过对两个区域重构电力市场不同情况下的发电需求交易进行仿真,验证了基于用户界面的系统频率调控的有效性。采用经典粒子群算法(PSO)求解积分控制器增益的最优值,以实现所研究系统的最优响应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimized unscheduled interchange based secondary control for two area deregulated electricity market
This paper describes the design and simulation of Unscheduled Interchange (UI) based optimized integral controller of Automatic Generation Control (AGC) in the restructured power system. The traditional AGC loop is replaced with UI based price signal linking to the frequency at the prevailing time. UI rate for corresponding system frequency signal is received from load dispatch center and it is compared with the marginal cost of individual generators to generate the error signal which decides the gain of integral controller for correction in frequency to its nominal value. The simulation is carried out for different cases of generation-demand transactions for two area restructured electricity market to demonstrate the effectiveness of UI based control in system frequency regulations. A non derivative classical Particle Swarm Optimization (PSO) technique is used to obtain the optimal value of gain of integral controllers to achieve the optimum response of the system under study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信