Ayan Mallik, J. Lu, Shenli Zou, Peiwen He, A. Khaligh
{"title":"单相交错图腾极PFC整流器的最小浪涌启动控制","authors":"Ayan Mallik, J. Lu, Shenli Zou, Peiwen He, A. Khaligh","doi":"10.1109/APEC.2018.8341096","DOIUrl":null,"url":null,"abstract":"Smooth start-up to limit the inrush current is an important requirement in development of actively controlled power factor correction (PFC) rectifiers. In this paper, a thorough mathematical analysis is conducted to exploit the transient behavior during the start-up and thus, the expression for maximum inrush current is determined. Based on the analyses, a specifically designed start-up technique by controlling the time instant of engaging the PFC control loop is proposed, which achieves smooth start-up with zero current over/undershoot. As a proof-of-concept, experimental measurements are conducted at 1.5kW to validate the theoretical predictions. It is observed that there is no occurrence of inrush during the PFC start-up and also, unity power factor is maintained along with an efficiency of 98 % and input current THD below 5%.","PeriodicalId":113756,"journal":{"name":"2018 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Minimum inrush start-up control of a single-phase interleaved totem-pole PFC rectifier\",\"authors\":\"Ayan Mallik, J. Lu, Shenli Zou, Peiwen He, A. Khaligh\",\"doi\":\"10.1109/APEC.2018.8341096\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Smooth start-up to limit the inrush current is an important requirement in development of actively controlled power factor correction (PFC) rectifiers. In this paper, a thorough mathematical analysis is conducted to exploit the transient behavior during the start-up and thus, the expression for maximum inrush current is determined. Based on the analyses, a specifically designed start-up technique by controlling the time instant of engaging the PFC control loop is proposed, which achieves smooth start-up with zero current over/undershoot. As a proof-of-concept, experimental measurements are conducted at 1.5kW to validate the theoretical predictions. It is observed that there is no occurrence of inrush during the PFC start-up and also, unity power factor is maintained along with an efficiency of 98 % and input current THD below 5%.\",\"PeriodicalId\":113756,\"journal\":{\"name\":\"2018 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2018.8341096\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2018.8341096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Minimum inrush start-up control of a single-phase interleaved totem-pole PFC rectifier
Smooth start-up to limit the inrush current is an important requirement in development of actively controlled power factor correction (PFC) rectifiers. In this paper, a thorough mathematical analysis is conducted to exploit the transient behavior during the start-up and thus, the expression for maximum inrush current is determined. Based on the analyses, a specifically designed start-up technique by controlling the time instant of engaging the PFC control loop is proposed, which achieves smooth start-up with zero current over/undershoot. As a proof-of-concept, experimental measurements are conducted at 1.5kW to validate the theoretical predictions. It is observed that there is no occurrence of inrush during the PFC start-up and also, unity power factor is maintained along with an efficiency of 98 % and input current THD below 5%.