P. Ratsamee, Thanarat Hanwong, Harn Sison, Kaned Thungod
{"title":"无人机两步灭火毯释放机构","authors":"P. Ratsamee, Thanarat Hanwong, Harn Sison, Kaned Thungod","doi":"10.20965/jrm.2023.p1053","DOIUrl":null,"url":null,"abstract":"Using fire blankets is one effective option for fire extinguishing. This paper proposes a two-step release mechanism for unmanned aerial vehicles (UAVs) that can precisely drop a blanket onto a target location using the advantage of wind load, avoiding the ground effect. We analyzed wind velocity under the UAV body to find the optimized range that maximizes the release of the fire blanket. Afterwards, we tested the performance of our proposed system in an indoor environment with simulated wind disturbance. Our experiment results showed that the system is robust against wind disturbance at 3.5 m/s. Finally, we tested our system with UAVs in an outdoor environment with different heights and proved the effectiveness of the system for up to 4 m height in an outdoor environment.","PeriodicalId":178614,"journal":{"name":"J. Robotics Mechatronics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Two-Step Fire Blanket Release Mechanism for Unmanned Aerial Vehicles\",\"authors\":\"P. Ratsamee, Thanarat Hanwong, Harn Sison, Kaned Thungod\",\"doi\":\"10.20965/jrm.2023.p1053\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Using fire blankets is one effective option for fire extinguishing. This paper proposes a two-step release mechanism for unmanned aerial vehicles (UAVs) that can precisely drop a blanket onto a target location using the advantage of wind load, avoiding the ground effect. We analyzed wind velocity under the UAV body to find the optimized range that maximizes the release of the fire blanket. Afterwards, we tested the performance of our proposed system in an indoor environment with simulated wind disturbance. Our experiment results showed that the system is robust against wind disturbance at 3.5 m/s. Finally, we tested our system with UAVs in an outdoor environment with different heights and proved the effectiveness of the system for up to 4 m height in an outdoor environment.\",\"PeriodicalId\":178614,\"journal\":{\"name\":\"J. Robotics Mechatronics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"J. Robotics Mechatronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20965/jrm.2023.p1053\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"J. Robotics Mechatronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20965/jrm.2023.p1053","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

使用消防毯是灭火的一种有效选择。本文提出了一种用于无人机的两步释放机制,该机制可以利用风荷载的优势,精确地将毯子投放到目标位置,避免地面效应。通过对无人机机体下风速的分析,找到了最大限度释放灭火毯的最佳范围。随后,我们在模拟风干扰的室内环境中测试了我们提出的系统的性能。实验结果表明,该系统对风速为3.5 m/s的风扰动具有较强的鲁棒性。最后,我们在不同高度的室外环境中用无人机测试了我们的系统,并证明了该系统在室外环境中高达4米高度的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Two-Step Fire Blanket Release Mechanism for Unmanned Aerial Vehicles
Using fire blankets is one effective option for fire extinguishing. This paper proposes a two-step release mechanism for unmanned aerial vehicles (UAVs) that can precisely drop a blanket onto a target location using the advantage of wind load, avoiding the ground effect. We analyzed wind velocity under the UAV body to find the optimized range that maximizes the release of the fire blanket. Afterwards, we tested the performance of our proposed system in an indoor environment with simulated wind disturbance. Our experiment results showed that the system is robust against wind disturbance at 3.5 m/s. Finally, we tested our system with UAVs in an outdoor environment with different heights and proved the effectiveness of the system for up to 4 m height in an outdoor environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信